IMPORTANT INFORMATION
Please read this guide carefully before
installing or maintaining this equipment.
Data should be used as an
INDICATION
only.
▪
Good electrical practices should be followed
at all times.
▪
Must only be installed by a licensed
electrician.
▪
If the external flexible cable or cord of this
luminaire is damaged, it shall be exclusively
replaced by the manufacturer or their
service agent or a similar qualified person in
order to avoid a hazard.
▪
For indoor use only.
▪
A qualified electrician, in accordance with
AS/NZS 3000:2007 wiring regulations
should carry out connection to mains
wiring.
▪
This unit must be
EARTHED
.
▪
Ensure that the rated voltage and frequency
requirements are compatible with the
available mains supply, 220-240V 50Hz.
▪
Cleaning of reflectors and lenses should be
carried out using clean, soft and lint free
cloths and anti-static cleaning fluid.
▪
Do not carry out high voltage insulation
test i.e. 500/1000V this may damage the
fixtures electrical components.
Warning - Applicable to New Zealand (Only)
This luminaire is not suitable for installation in
locations where thermal insulation is present,
or may reasonably be expected to be installed
in the future, or where there is a likelihood of
other combustible material, e.g. Leaves or vermin
debris, etc. collecting on or around the luminaire.
It is not suitable for domestic installations or
installation in residential areas of non-domestic
installations (residential institutions, hotels,
boarding houses, hospitals, accommodation
houses, motels, hostels and the like).
Luminaire’s light distribution is direct.
Luminaire is designed for the T5-light source’s unique
characteristics. The small diameter of the fluorescent lamp
has created new conditions for light control.
IP20
IP CLASSIFICATION
IP20 : Protected against solid objects greater than 12mm.
e.g. Persons fingers.
CLASS I
Appliances with functioning insulation. Equipped with an
earth termination.
RISK OF FIRE
a. The minimum clearance distance from the top of the
luminaire to any normally flammable building element
is 100mm.
b. The minimum clearance distance from the top of the
luminaire to any building insulation is 100mm.
c. The minimum clearance distance from the side of the
luminaire to any normally flammable building element
is 100mm.
d. The minimum clearance distance from the side of the
luminaire to any building insulation is 100mm.
WARNING – RISK OF OVERHEATING OR FIRE IF THE
CLEARANCE DISTANCES ARE COMPROMISED.
Luminaire is available in designs for conventional emergency
lighting operation.
RCM
Indicates a device’s compliance with applicable ACMA
technical standards.
INSTALLATION INSTRUCTIONS