background image

01

02

03-04

05

06

07

08-11

12

13-14

Component

 

Struction

Water

 

and

 

wire

 

line

 

instruction diagram

Connecting diagram of faucet pipe

Installation

 

steps

Faucet

'

s

 

usage

 

instruction

Wire connection diagram for computer box

Control panel usage instruction

Troubleshooting

Maintenance Card

1. Please read carefully and follow all instructions when operating.

2. Qualified earth leakage circuit-breaker must be installed and 

    tested with trial jump to certify the device is qualified and safety 

    before using the product.

3. To avoid electrical shock, the replacing of the wire must be done 

    by the electrical engineer or the retailer. Customer could not 

    replace by yourself. 

4. Ground wire of massage water pump and air pump must be 

    connected to ground well, the minimum size copper wire of ground 

    wire must not be less than 1.5mm².

5. It is forbid to remodel, add or take part products.

6. Please don't use this product after alcohol or drugs.

7. The children shall be closely supervised by parents to use product.

8. All the electrical spare parts except the remote control must be put 

    suitable and stable to avoid slip into the tub.

9. Warning: the mixed water temperature shall never exceed 60 

    degree centigrade.

10. Don’t use sulphuric acid, hydrochloric acid, lye and other mixed 

    strong corrosive chemical liquid to clean product.

11. The water pump would be very hot when running. Please don’t 

    touch the surface of the machine to avoid scald.

12. The water level must be higher than the jet before turning on the 

    product.

13. Please don’t drop anything in or insert water pump and the 

    opening hole of machine.The socket position should be suitable. 

14. Warning - To prevent risk of electric shock, please connect the 

    GFCI / RCD (earth leakage protection device) socket.

15. Warning - To prevent electric shock, please do not connect any 

    extension cord to the power supply.

16 Caution - please use the product under the following condition: 

    water pressure is 0.15 ~ 0.40MPa, the ground must have the  

    ability to support the estimated load, water can not exceed the 

    overflow level, the washroom need to reserve enough space for 

    proper to handle the overflow of water.

17. WARNING - for bathtub to be used normally please do not grasp 

   the hand wheel drainer, nozzles, piping, handrails, etc.,to cause 

   any leakage and other problem when unpacking the product.

Safety Information

Maintenance instruction

1. Clean the acrylic surface:

Clean acrylic surface with cotton flannel or sponge and water in daily life. If there
is scratch on the surface, please use No. 1500 water abrasive cloth polishing 
slightly to clear away scratches, and then polish with toothpaste, cotton flannel. 
Please don’t use strong caustic chemical liquid, such as sulphuric acid, 
hydrochloric acid, lye during maintenance.

2. Plated item maintenance:

Clean the surface of plated item with cotton flannel, please don’t use coarse cloth.

3. Suction net cleaning:

Turn the screw out and take the suction net out to clean dirt, to keep the water 
going through smoothly. Don’t use strong causticity chemical liquid to clean the 
product, such as sulphuric, hydrochloric acid, lye and so on.

Summary of Contents for AM156

Page 1: ...Installation Instruction of AM156 TS series Control panel ...

Page 2: ...ust be higher than the jet before turning on the product 13 Please don t drop anything in or insert water pump and the opening hole of machine The socket position should be suitable 14 Warning To prevent risk of electric shock please connect the GFCI RCD earth leakage protection device socket 15 Warning To prevent electric shock please do not connect any extension cord to the power supply 16 Cauti...

Page 3: ...anel Pillow Hand shower holder Hand shower Three piece faucet Drain valve Movable straight pipe 0 5 Inch three way Side jet Bathtub Waterfall Bottom light Drain Suction Speaker Speaker installation panel 4CM conversion 1 Inch inclined pipe Fitting nut One way stuff 1 Inch three way Heater Junction box PC board clip Lengthened plastic Water pump Stainless steel bracket AM156 Water and wire line ins...

Page 4: ...03 Installation Instruction 04 Am156 Hot water switch Cold water switch ...

Page 5: ...aucet A Function conversion value Turn 90 left is the pipe cleaning function while 90 right is the shower head B The water in pipe where with blue label is cold water and the hand hole faucet with label C is also cold water Turning left could alternate the volume of the cold water The maximum is 90 to the left C The water in pipe where with red label is hot water and the hand hold faucet with labe...

Page 6: ...er level sensor Light color is change automatically Speaker Radio antenna Water temperature probe Control panel Only can be matched the DC12V ozone generator 250 Crimp terminal 250 Crimp terminal 250 Crimp terminal 250 Crimp terminal Thermostatic power Main power Water pump power Electric parameter Spare part Parameter Rate voltage Rate voltage Rate power Massage pump Ozone generator Bottom light ...

Page 7: ... The volume range is 0 20 8 6 Channel saving channel picking out 8 6 1 Channel saving select the channel need to save when the radio turns on touch the LCD flicker CH icon touch or to choose the saving position the channel can be saved in this position when touch for 2 seconds again The characteristics of the control system electrical box 1 Rated voltage AC220V 240V AC110V 120V 2 Rated frequency 5...

Page 8: ...r pause music 9 6 Touch bluetooth music playing function turns on LCD flicker VOL and number means the volume can be adjusted Touch or to adjust volume 10 Heater 10 1 The heater can not be turned on until the surfing water pump turns on 10 2 Touch to turn on the heater function LCD constant shows icon The heater would start or stop to work according to the o temperature inside the bathtub and the ...

Page 9: ...13 Installation Instruction 14 ...

Reviews: