background image

                                                                

 

 

 

 

              

                                                                                                                

 

 

WARNING:    

BEFORE YOU START TO USE  READ AS FOLLOWS 

INFORMATION

 

Safety information : 

1.

  For  best  performance,  please 

read 
this manual carefully.  
 Keep  it  in  a  safe  place  for  future 
reference. 

2.

  Install  the  unit  in  a  cool,  dry, 

clean  place  away  from  windows, 
heat  sources,  intense  vibration, 
dust,  humidity,  cold,  and  sources 
of humming (transformers, motors, 
etc.)..  To  prevent  fire  or  shock 
hazard  do  not  expose  the  unit  to 
water 

and 

moisture. 

3

.  Never  open  the  equipment.  If 

something  should  get  into  all 
'inside, 

contact 

your 

dealer. 

4.

 Do not operate the switches and 

other  controls  with  force.  When 
moving  the  unit,  first  disconnect 
the 

power 

cord 

and 

cables 

connected  to  other  devices.  Never 
pull the wires themselves.

 

 

5.

  The  openings  of  the  lid 

provides  adequate  ventilation  of 
the unit. In case of obstruction of 
the same, the temperature inside 
the rooms very quickly.  
Then  install  the  unit  in  a  well-
ventilated 

place, 

avoiding 

placing various objects in front of 
these  openings  to  prevent  fire 
and damage.Leave a space of at 
least  20  cm  behind,  20  cm  on 
both sides and 30 cm above the 
top  panel  of  the  machine  to 
avoid  fire  or  other  damage. 

6

.  The  voltage  used  must  be 

specified. 
 Using this product with a current 
whose  voltage  is  higher  than 
specified  is  dangerous  and  may 
cause  fire  or  other  damage. 
EAM  LAB  is  not  responsible  for 
any  damage  due  to  an  incorrect 
use of the appliance

 

 

Summary of Contents for Element 302

Page 1: ...reat detail by our entire staff to strict quality control This dedication was followed throughout the wole manufacturing process from basic research the selection of each parts assembly and testing so that we could supply a product with every confidence that it will give full owner satisfaction and pride We welcome you to the fast growning Eam Lab circle of dedicated audio enthusiasts and true sou...

Page 2: ...A High dynamic current amplifier interface to better the various components of the audio chain by providing a sound exciting and free of stains The most important components equipped this product are entirely building in Italy under tight tolerance specifications The capacitors power transformer and stainless chassis are designed for reduce vibration the primary cause of a sound inhomogeneous The ...

Page 3: ...s 2 Introduction features 3 Table of contents 4 Safety instructions 5 Unpackaging preparation 6 Function protection 8 Front pannel function 9 Connections 10 Troubleshooting guide 11 Datasheet 12 guarantee policy ...

Page 4: ...ving the unit first disconnect the power cord and cables connected to other devices Never pull the wires themselves 5 The openings of the lid provides adequate ventilation of the unit In case of obstruction of the same the temperature inside the rooms very quickly Then install the unit in a well ventilated place avoiding placing various objects in front of these openings to prevent fire and damage...

Page 5: ...rs worth the irreparable damage to speakers connected Before the installation remove your amplifier taking care to keep it in the future if you ever require to be shipped to a service center EAMLAB to be overhauled or repaired Installation thanks to its ease of use there are no particular notes of difficult interpretation Before making any connections make sure that the amplifier is turned OFF pre...

Page 6: ...elay antibump The LEDs become fixed after about 3sec 2 resets the parameters of current and voltage of the output stages to ensure maximum efficency 3 immediately disconnects the load in case of failure of the transistors 4 disconnect the load in the event of a short circuit on the output stages 5 disconnect the load in the event of a short circuit on the power cables 6 disconnect the load in the ...

Page 7: ... the warranty THLTM thermal overload The thermal protection system THLTM is controlled with microprocessor Thl is designed for maintain exercise temperature under 70 Celsius Activated only in the case in which the operating temperature of the final stages exceeds the threshold of 100 The intervention THL will be signaled by the fixed LEDs on the front panel see fig these LEDs will light when the h...

Page 8: ...8 Turn ON OFF power amp ILP status led of protection or DC offset output THL status led of temperature control Stand by led Front pannel function ...

Page 9: ...R or RCA Left and Right output to connect speaker min 2 Ohm Front pannel back light ON OFF General switch ON OFF Powercord and service fuse Connection 1 Trigger control For turn ON OFF amplifier with preamplifier remote control when trigger cable is interconnect 1 ...

Page 10: ...equipped with such control THL light and amplifier no power output Output relay open temperature is in overload up to 90 when down to 80 relay closed automatically THL light and amplifier turn OFF Temperature much to high Temperature over 100 Celsius Amplifier turn on automatically when temperature down 70 Trigger interconnection no turn ON OFF amplifier Cable KO or source imcompatibilities Check ...

Page 11: ...to 80 Khz 0 3db 80Khz to 150Khz 4 db Crest factor 20db Input sensivity 1 3 Volt rms for full power 8 ohm XLR RCA Power consumption Stand by 1W Idle 30 W Maximum 1800W System protection ILP intelligent lock power THL thermal heat limiting via CPU PSS power soft starting via CPU CMMR 70 db Channel separation 80db Circuit topology AB class in dual mono configuration Max voltage out per channel 58 Vol...

Page 12: ...Website www eamlab com To contact EamLab service How to return a product To return a product to EAMLAB please follow this procedure so that we may serve you better 1 Obtain a Return Authorization Number R A number and shipping address from the Krell Service Department 2 Insure and accept all liability for loss or damage to the product during shipment to the Krell factory and ensure all freight shi...

Reviews: