Table 1-1. SPECIFICATIONS
FREQUENCY COVERAGE:
10 kHz to 5 MHz
GAIN:
53 dB min, ±1.5 variation
CLASS AB OUTPUT:
200 watts
SATURATED RF POWER OUTPUT:
300W Min.
from 30kHz - 4MHz;
INPUT IMPEDANCE:
50 ohms, VSWR, 1.5:1 Maximum
OUTPUT IMPEDANCE:
50 ohms, VSWR, 2:1 Maximum
STs STABILITY:
Continuous operation into any load or
source impedance
PROTECTION:
Unit will withstand a + 13dBm input
signal (1.0 Volts RMS), without damage.
And all load conditions at rated Power
out
POWER OUTPUT METER:
RMS power detection. ±3% of full scale
accuracy, 100 KHz - 1 MHz. 10-100 KHz
see table below. Above 1 MHz ± 10%
POWER REQUIREMENTS:
100
– 240 VAC 47-63 Hz.
SIZE:
5.3
” x 16.5” x 18.4”
134.5 x 420 x 467 mm
WEIGHT:
32.5 pounds (14 kg)
CONNECTORS:
BNC
OPERATING TEMPERATURE:
0
– 40 C
RACK MOUNTING:
For frequencies below 100 KHz see table below for error correction factors. To
obtain accurate RMS power number increase the front panel reading by the
percentage corresponding to the frequency of use as seen below.
Frequency Corretion factor
MHz
%
0.01
13.0%
0.02
8.0%
0.03
5.8%
0.04
4.8%
0.05
4.5%
0.06
3.5%
0.07
3.0%
0.08
2.5%
0.09
2.8%
0.1