background image

The material contained in this document is the property of Electronics & Innovation Ltd., it is subject 
to change without notice.  

 

February 2007                                                        Page 5 of 17                                                       Revision C 

 
2.8 Front Panel Display 
 

The 325LA front panel has a passive LCD display designed for simplicity and ease of use.  During 
initialization, the LCD shows the software revision.   

Pf:___W Pr:___W 

Status:________

 

Figure 2.1 : Front Panel Display 

After the amplifier is initialized, the LCD indicates Forward Power, Reflected Power, and amplifier 
status (see figure 2.1). Where Pf refers to forward power, Pr refers to reverse power, and Status 
indicates “OK” unless there is a fault condition, such as: 

  Overheat (heat-sink temperature is too high for reliable operation) 

  PSU fault (internal fault in the main switching power supply) 

In the event of a fault, the unit may be reset by either cycling the power or via the RS 232 
interface. In the case over an over temp fault, ensure that the air inlet and out let are 
unclogged and unrestricted.  If the fault persists, please contact E&I or your local 
representative. 

 

 

 

 

 

 

 

 

 

 

 

2.9 RS 232 Interface 

The 325LA features a standard RS-232 serial interface suitable for connection to a PC or 
host system.  The communication protocol is extremely simple to facilitate readback and 
control with readily available terminal programs such as Hyperterm.  The RS-232 link has 
the following parameters: 

Baud rate: 

19200 

Data bits: 

Parity:   

none 

Stop bits: 

Summary of Contents for 325LA

Page 1: ...furbished and purchasing new Financing options such as Financial Rental and Leasing are also available on application TMG will assist if you are unsure whether this model will suit your requirements C...

Page 2: ...tice February 2007 Page 1 of 17 Revision C 325LA Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT All operating personnel should use extreme caution in handling the...

Page 3: ...it fully operational such that it performs according to the original specifications free of charge to the original purchaser Should warranty service be required the unit must be returned to E I freigh...

Page 4: ...d on the front panel meter The Model 325LA is packaged for bench mounting and can be supplied with rack mounting adapters It has an integral power supply which operates from an 85 264 VAC 47 63 Hz mai...

Page 5: ...ng brackets to the sides of the unit using the screws removed in step b 2 5 Mains Lead Connection The unit comes supplied with a 6 foot mains cord 2 6 Cooling When the 325LA is enclosed by an external...

Page 6: ...ess there is a fault condition such as Overheat heat sink temperature is too high for reliable operation PSU fault internal fault in the main switching power supply In the event of a fault the unit ma...

Page 7: ...the front panel LCD display allowing a running datalog to be stored to disk using the capture feature of the terminal program Single character commands can be sent to the amplifier to achieve the fol...

Page 8: ...er The unit is designed to withstand 100 reflected power a pure reactance open or short circuit load will cause 100 reflected power continuously without damage An output meter is provided to indicate...

Page 9: ...inates ii Connect the output of the 325LA amplifier to 20 dB attenuator iii Connect a calorimetric power meter HP434 or equivalent to the output of the attenuator iv Connect a sweep generator Wavetek...

Page 10: ...3 then proceed as follows d Adjust the sweep Signal generator at a CW center frequency of 150 MHz for an indicated output of 25W on the power meter e Using the spectrum analyzer check that the level o...

Page 11: ...M3 screws on the side of the unit The rear panel supports the mains fuse holder AC line cord and the cooling fan 4 4 Power supply The power supply is mounted vertically on the right hand side of the a...

Page 12: ...Electronics Innovation Ltd it is subject to change without notice February 2007 Page 11 of 17 Revision C Appendix Figures Figure 1 325LA Specifications Figure 2 Front and Rear View Figure 3 Gain Test...

Page 13: ...60Hz 1 7A Power Output Display Forward and Reverse power in Watts with an accuracy of 5 Noise Figure 10 dB Maximum Typical 3rd Order Intercept Point 53dBm Stability Continuous operation into any load...

Page 14: ...The material contained in this document is the property of Electronics Innovation Ltd it is subject to change without notice February 2007 13 Revision B Figure 2...

Page 15: ...nt is the property of Electronics Innovation Ltd it is subject to change without notice February 2007 14 Revision B Figure 5 Figure 4 Power Sweep RF 150 KHz 300 20 dB Attenuator Spectrum Power Power S...

Page 16: ...S1 Thermal switch 1 2 50 ohm 100W J2 Front panel RF input 0dBm Controller Fwd_in Rev _in TX RX f p_tx f p_Vdd f p_gnd DC Status PSU Enable PSU Enable ret DC Status_ret ov erheat_rtn ov erheat gnd gnd...