0m
2,916m
0,044m
2,104m
2,13m
0,836m
2,900m
0,935m
1,060m
1,129m
1,200m
2,770m
2,028m
2,054m
1,981m
2,080m
2,660m
2,000m
DRIVEN 6
COAX ELEMENT
DRIVEN 4
REFLECTOR 4
REFLECTOR 6
DIRECTOR 6-1
DIRECTOR 4-1
DIRECTOR 4-2
DIRECTOR 6-2
PLACA/ PLATE
Page 1: ...e quality All the hardware is stainless Steel W4 The aluminium used is T5 6061 6063 and T6 6082 the best alloys for manufacturing antennas with extreme weather resistance Weather was double here EAnte...
Page 2: ...dBi 8 58 dBi F B 20 43 dB 18 76 dB SWR 1 0 1 1 4 1 1 0 1 1 3 1 Impedance 50 Ohms 50 Ohms Max Power 10 kW 10 kW Boom Length 2 05m 6 72 Wind Survival 160kmh 100mph Weight 5 1 Kg 11 3 Pounds 14 0 21 0 M...
Page 3: ...04m 2 13m 0 836m 2 900m 0 935m 1 060m 1 129m 1 200m 2 770m 2 028m 2 054m 1 981m 2 080m 2 660m 2 000m DRIVEN 6 COAX ELEMENT DRIVEN 4 REFLECTOR 4 REFLECTOR 6 DIRECTOR 6 1 DIRECTOR 4 1 DIRECTOR 4 2 DIREC...
Page 4: ...e para no da ar ninguna rosca del BOOM EA010039 EA010039 EA010039 EA010039 EA010039 EA010039 DIN 933 M6X16 DIN 9021 M6 ESPA OL BOOM BOOM A A DIN 933 M6X16 DIN 9021 M6 ENGLISH To mount the BOOM you hav...
Page 5: ...que los dem s elementos pero teniendo en cuenta que los tornillos que utilizaremos son DIN 912 M6X40 y tuercas autoblocante DIN 985 M6 una vez que est ensamblada toda la antena S912 9640 DIN 912 6x40...
Page 6: ...mind that the head of the screw has to be housed inside the hollow of the element and in the other side the rivet has to be inserted to be screwed with the Allen key supplied See example below Measur...
Page 7: ...hagan la mayor fuerza sobre el m stil mediante abarcones redondos de M8 Los abarcones redondos de M8 A 0163 van fijados mediante arandela DIN 9021 M8 y tuerca DIN 934 M8 proporcionadas en el mismo ab...
Page 8: ...he mast by means of M8 round U bolts Round U bolts M8 A 0163 are secured by washer DIN 9021 M8 and nut DIN 934 M8 provided in the same U bolt and fixed to the mast with clamp 23035 50 Detailed drawing...
Page 9: ...imentaci n Simplemente abrir el coaxial y soldar los 2 terminales suministrados despu s colocando estos en los tonillos del elemento de alimentaci n DRV 6 y fijandolo con las tuercas y arandelas La po...
Page 10: ...tenna being 1 or 2 meters above the ground is enough give us the ame result being any other height and put in the tower mast Feeding When the installation is fully completed the last step is feed the...
Page 11: ...12mm 14 RIVSS_M4 PART PIEZA N IMAGEN PART IMAGE DESCRIPCION DESCRIPTION MEDIDAS SIZES CANTIDAD QUANTITY EA013018 Placa M stil Boom Mast and Boom plate 100 x 100 x 6mm Abarcon U Bolt Mordaza Tube Clam...
Page 12: ...Elementos Elements plates Placa para Elementos Elements plates 150x50x4mm 3 EA010026 Placa para Elementos Elements plates 150x50x4mm 3 EA010024 DIN 985 M6 32 S985 906 EA010025 150x100x4mm 1 EAHYP013 P...
Page 13: ...x 10mm 1458mm x 13mm 1052mm x 13mm 1423mm x 13mm 1000mm x 13mm 1385mm x 13mm 1014mm x 13mm 1000mm x 13mm 1330mm x 13mm 1 1 4 2 2 2 2 2 2 2 2 50OWA8 A 50OWA8 B PACKING LIST LISTA DE PIEZAS REFLECTOR 6m...