EN
25
HV4901
Malfunction
Cause
Remedy
Paint in the
ventilating hose
•
Diaphragm soiled
•
Diaphragm defective
➞
Clean the diaphragm
➞
Replace the diaphragm
Device does not
function
•
Device overheated
➞
Unplug the power
plug, let the device
cool down approx. 30
minutes, do not bend
the hose, check the air
filter, do not cover the
intake slots
Poor covering
capacity on the
wall
•
Spray material is too cold
•
Highly absorbent surface or paint
with poor covering capacity
•
Distance too large
➞
The material you are
spraying should be at
room temperature
➞
Cross spray (Fig. 12)
➞
Closer to the object
25. Technical Data
Technical Data
Power source
230 V
~
, 50 Hz
Power consumption
760 W
Double insulation
Air hose length
3.5 m
Weight
approx. 3.3 kg