16. Cleaning the Fluid Tip and Needle

1)   Unscrew Air Cap Ring (Fig. 9, 1)

2)   Remove Spray Direction Lever (Fig. 9, 3)

3)   It is recommended that you push the trigger forward to help release the Fluid Tip (Fig. 9, 4)

4)   Using the Needle and Fluid Tip Tool - pincer end (Fig. 10, 1) remove the Fluid Tip 

(Fig. 10, 2)

5)   Insert the Needle and Fluid Tip end (Fig. 10, 1) into the inner tube and unscrew the 

Needle anticlockwise, then pull to release the Needle (Fig. 10)

6)   Place all of these items into a container and clean, then using a brush and the 

respective thinners

7)   Clean the inside of the body of the gun

8)   Thoroughly dry these parts before reassembling

9)   Reassemble parts in reverse order. (Fig. 11)

10)  Ensure the Air Cap Ring (Fig. 9, 1) is fully tightened and the Fluid Tip (Fig. 9, 4) is 

pushed into place so that the Needle (Fig. 9, 5) will shut off 

Note: Ensure the Spray Direction Lever (Fig. 9, 3) is free to move. If necessary loosen the 

Air Cap Ring (Fig. 9, 1) slightly.

NEVER DISPOSE OF PAINTS OR SOLVENTS DOWN THE DRAIN. ALWAYS USE YOUR 

LOCAL WASTE COLLECTION SITE. 

17. Maintenance

1)   Ensure the Filter (Fig. 12 A) is kept clean at all times.

2)   This can be washed out if necessary and replaced when dry. From time to time this 

filter will need replacing.

3)   The turbine bearings are sealed and lubricated for life. There is no maintenance or 

adjustment required.

4)   Clean the turbine and hose unit with a damp cloth after use.

WARNING!   Never operate the machine without the air filter fitted; otherwise 

dirt could be sucked in and impair the function of the machine.

Summary of Contents for SPRAY SYSTEM HV 1900

Page 1: ...Spraystation HV1900 Operating Manual EN...

Page 2: ...HV1900 1 6 3 2 1 4 7 3 A Spraystation HV1900 Operating Manual EN B A 2 5A 5B B...

Page 3: ...HV1900 4 5 A B C 7 A C 20 30 cm B 6...

Page 4: ...HV1900 A B 12 8 2 1 10 NEED IMAGE NEED IMAGE 1 2 4 6 5 9 7 8 3 1 2 3 4 11...

Page 5: ...s 1 Explanation of symbols used 2 2 General Safety Instructions 2 3 Safety Instructions for Spray Guns 4 4 Description Scope of delivery 5 5 Field of application 6 6 Coating Materials Suitable for Use...

Page 6: ...sorderly or unlit workplaces may result in accidents b Never use the tool in hazardous areas that contain flammable liquids gases or dusts Power tools generate sparks that can ignite the dust or vapou...

Page 7: ...ch as dust mask non slip safety shoes safety helmet or ear protection depending on the type of power tools reduces the risk of injury c Avoid accidental starting up Make sure that the electric tool is...

Page 8: ...aged parts repaired before using the tool Many accidents have their origin in power tools that have been maintained badly f Use the power tool accessories insert tools etc in accordance with these ins...

Page 9: ...ces of ignition such as for example open fires smoke of lit cigarettes cigars and tobacco pipes sparks glowing wires hot surfaces etc in the vicinity during spraying Ensure that no solvent vapours are...

Page 10: ...as a consequence of sprayed material entering the socket outlet Mask all the areas and objects that are not to be spray painted or remove them from the work area No liability is assumed for damage du...

Page 11: ...nds HV5500 130 seconds HV5901 150 seconds To thin paint add water to water based paints and white spirit to oil based paints i Spray material that is at least at room temperature provides a better spr...

Page 12: ...on the rear of the spray gun Fig 6 turn upwards higher material volume turn downwards lower material volume 13 Spray Technique i The spray result depends heavily on the smoothness and cleanliness of t...

Page 13: ...s after an interruption in operation 15 Taking Out of Operation and Cleaning Propercleaningistheprerequisiteforproblem freeoperationofthepaintapplication device No guarantee claims are accepted in cas...

Page 14: ...order Fig 11 10 Ensure the Air Cap Ring Fig 9 1 is fully tightened and the Fluid Tip Fig 9 4 is pushed into place so that the Needle Fig 9 5 will shut off Note Ensure the Spray Direction Lever Fig 9 3...

Page 15: ...35 1 5mm Fluid Tip Needle Seal EAR2353925 2 0mm Fluid Tip Needle Seal EAR2353952 2 5mm Fluid Tip Needle Seal EAR2353987 3 0mm Fluid Tip Needle Seal EAR2353956 1l Pot Lid EAR2354031 20 Environmental pr...

Page 16: ...ial volume adjuster Tighten container Refill Insert Clean Coating material drips from the nozzle Coating material clogged at air cap nozzle or needle Nozzle loose Nozzle seal worn Nozzle worn Clean Ti...

Page 17: ...entilating hose Diaphragm soiled Diaphragm defective Clean the diaphragm Replace the diaphragm Poor covering capacity on the wall Spray material is too cold Highly absorbent surface or paint with poor...

Page 18: ...any electrical dealer for a replacement or ring our helpline 4 A replacement fuse must be rated at 5 Amps and manufactured and approved to BS 1362 5 IFINANYDOUBTCONTACTAQUALIFIEDELECTRICIAN If you ne...

Page 19: ...tool isopenedupby personsotherthanmanufacturerservice personnel Transport damage maintenance work and loss and damage due to faulty maintenance work are not covered by the guarantee Under any guarante...

Page 20: ...2006 42 EC 2004 108 EC 2011 65 EU 2002 96 EC 2006 95 EC Applied harmonised norms EN 60335 1 2012 EN 62233 2008 EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 Corrigendum 1997 A1 2001 A2 2008 EN 6100...

Page 21: ...EN 17 HV1900...

Page 22: ...8060 M r 36 22 407 321 36 22 407 852 DK S Wagner Spraytech Scandinavia A S Helgesh j All 28 DK 2630 T strup 45 43 27 18 18 45 43 43 05 28 E Makimport Herramientas S L C M jico n 6 Pol El Descubrimien...

Reviews: