24
This is expected under annual system start up. If this
occurs during normal operation then make sure the
furnace is working properly and contact your Earth Factory
Service Representative.
Standby LED on continuously:
The purpose of the Standby mode is to prevent extended
heating of the catalyst and running of the damper and
blower when the furnace is low on fuel.
Try the following operations to isolate the problem:
•
Remove ash from the furnace then add fuel
•
Insure that the fire is burning well
•
Turn off the power and check dampers and blowers
for obstructions. Remove or clean out obstructions
and recycle the power to the IBC-3.1.
•
Turn the power switch behind the back cover of
the furnace on and off to reset. If this condition
persists then check to make sure the
Thermocouple cable is not wired backward.
Alarm/Alert LED flashes 2 times and then Alarm/Alert
LED off for 1 second
This condition indicates that the inside of the IBC-3.1 is
greater than 140°F
•
Check for overheated enclosure.
•
Make sure the IBC-3.1 is not mounted to the
furnace on a heated surface.
•
Make sure the IBC-3.1 is not in direct sun light
during temperatures in excess of 100 °F
•
Cycle the Power to Recover.
Post Cat. Thermocouple Sensor Under-range:
Alarm/Alert LED flashes 3 times and then Alarm/Alert
LED off for 1 second