35
Manual Lighting
CAUTION:
DO NOT attempt to light the pilot by hand.
1.
Locate the OFF/REMOTE slide actuator on the left rear
of the burner. Slide the actuator to the left / OFF position.
(Figure 51)
2.
Locate the ON/OFF switch at the front of the switch
box. Press the switch to the ON (I) position.
(Figure 52)
The igniter will begin to spark. After the pilot lights and
is established, the valve will automatically open and the
burner will light.
NOTE:
The ignition sequence will take approximately 5
seconds.
WARNING:
If the pilot fails to light within 10 seconds,
turn OFF the system. Allow five (5) minutes for any
gas in the unit to dissipate, then repeat step 2 above.
IF YOU SMELL GAS, SEE STEP B AT BEGINNING OF
LIGHTING INSTRUCTIONS.
If the pilot fails to light after several tries, turn the
system OFF and contact a qualifi ed professional service
technician.
NOTE:
In manual mode, the remote transmitter will not
operate the burner system.
Shutting Down
• For remote shut down, press the OFF button on the
remote transmitter. If remote is unavailable, slide the
OFF/REMOTE slide actuator (on left rear of burner) to the
left / OFF position.
• For manual shutdown, press the ON/OFF switch on the
front of the switch box to the OFF (O) position.
NOTE:
If the system needs to be relit immediately after
shutting down, the thermocouple will require 20 seconds
to cool down before the system can reignite.
Pilot Appearance
Periodically check the pilot for proper flame pattern.
The pilot flame should encircle the, and is preset at the
factory.
(Figure 53)
If the pilot flame burns incorrectly; shut down
completely and contact a qualified professional
service technician.
Earthcore Industries
08/2017
BVETTO B-Vent Gas Fireplace
ISOKERN Gas Log Set - Lighting Instructions
19
I
O
(cont.)
OFF/REMOTE slide actuator (left rear of burner)
Switch box, ON/OFF
Remote receiver
ON
OFF
Proper pilot fl ame
FIGURE 51
FIGURE 52
FIGURE 53