2/2021
ISOFLAMES OUTDOOR TABLE BURNER
2
Isoflames Outdoor Table Burner - Components List
Isoflames Outdoor Table Burner - Specifications
Gas Line Installation
This appliance must be connected to the gas line in accordance with local codes and/or the National Fuel Gas Code, ANSI Z223.1.
After connecting the gas line, all joints in the line and connections at the valve should be checked for leaks before final positioning
of the unit. Conduct a gas leakage test of the appliance piping and control system downstream of the shutoff valve in the supply
line to the appliance.
4
No.
Description
Part No.
Qty
1
Isoflames 18
”
Square Table Burner
ISF18STB
1
Isoflames 48
”
Linear Table Burner
ISF48LTB
1
2
Gas Regulator w/36" Hose adapter
ISF-E-GR
1
3
Key Valve w/Key
ISF-E-KV
1
4
Natural Gas Orifice #30
E-O30
1
5
LP Gas Orifice #48
E-O48
1
6
3/8" Flex Connector 34"
ISF-E-FC34
1
7
3/8" Flared fitting male adapter
ISF-E-FFM38
1
Burner Specifications
Minimum Clearance
Dimension (in)
BTU
Burner
Model
Below
Above
Sides
Nat.
Gas
L.P.
Gas
ISF18STB
6
72
24
65K
60K
ISF48LTB
6
72
24
65K
60K
BURNER CAVITY DIMENSIONS (in)
Burner
Model
A -
Height
(Min)
B - Width (Min)
C- Length
Min
Max
Min
Max
ISF18STB
6
18-1/2
20-1/2
18-1/2
20-1/2
ISF48LTB
6
8-3/8
10-1/2
47-3/8
49-1/2
TABLE 1
TABLE 2
TABLE 3
FIGURE 1
FIGURE 2
FIGURE 3
FIGURE 4
3