5)
Two steel angle irons with measurements of
6” x 6” x ½”
that are cut to span the width of the firebox will be needed to
assemble the 72”, 96”, and 120” fireboxes (not required for the 48” model).
It is necessary to cut four ½” deep recesses to properly seat the angle iron. These recesses shall begin at the front of the
top sidewall components and extend 5 ½” towards the center of the firebox. These notches ensure that the angle iron is
level and flush with the top of the side wall components.
When properly installed, the angle iron will protrude ½” beyond the front edge of the side wall components
(Figure 11)
.
NOTE
: It is not necessary to apply Earthcore Adhesive between angle and Isokern sidewall components.
NOTE
: The steel angle should not be longer than the width of the firebox.
NOTE
:
Angle iron is not included but required for installation
.
FIGURE 11