Warranty & Disclaimer

Isokern Fireplace 

Earthcore  offers  a  lifetime  warranty  for  all  Isokern  fireboxes,  to  be  free  from  defects  in  materials  that  

negatively affect system performance from the date of purchase, subject to the terms and conditions of this 

limited warranty.

This warranty covers only the above stated components, and NO WARRANTY, EXPRESS OR IMPLIED,

EXTENDS TO ANY OF THE HARDWARE, FOOTING, VENTS, DUCTING, METAL FLUES, FIRE 

BRICK OR ACCESSORIES. THIS WARRANTY DOES NOT COVER DRAFTING, SMOKING OR 

UFFING OF THE FIREPLACE SYSTEM. Factors beyond the manufacturer's control affect fireplace 

rafting, smoking, and puffing, and Earthcore cannot guarantee these aspects of performance.

If a component is found to be defective under the terms of this warranty the party to whom this warranty is

extended shall, notify Earthcore, 6899 Philips Industrial Blvd, Jacksonville, Florida 32256, in writing, by

registered mail, within thirty (30) days following the discovery of the defect within the lifetime warranty 

period. The notice shall contain (1) the date of purchase; (2) place of purchase; (3) address of installation; 

(4) name, address and phone number of the owner; and (5) a brief description of the defect.

Earthcore, or any division thereof, is not responsible for any labor costs or indirect costs incurred for the 

replacement of defective components.

Earthcore is not responsible for misuse or mishandling of components. Nothing in this warranty makes 

Earthcore, or any division thereof, liable in any respect for any injury or damage to the building or structure 

in which the fireplace or chimney system has been installed or to persons or property therein arising out of 

the use, misuse, or installation of properly manufactured ISOKERN product.

EARTHCORE, OR ANY DIVISION THEREOF, SHALL NOT BE HELD LIABLE FOR ANY INCIDENTAL 

OR CONSEQUENTIAL DAMAGES OR EXPENSES ARISING OUT OF THE USE OF THE FIREPLACES 

OR CHIMNEY SYSTEMS. ALL SUCH DAMAGES AND EXPENSES ARE HEREBY EXCLUDED.

This warranty is null and void when the fireplace or chimney systems are not installed pursuant to the 

installation instructions provided by Earthcore or local building codes have not been followed completely.

This warranty applies only to those fireplace and chimney systems installed in the continental United 

States, Alaska, and Canada. If any part of this warranty is found to be unenforceable, the remaining parts 

shall remain in force and effect.

EARTHCORE HEREBY DISCLAIMS ALL GUARANTEES AND WARRANTIES, EXPRESS OR 

IMPLIED, BEYOND THE WARRANTIES SET FORTH HEREIN.

6899 PHILIPS INDUSTRIAL BLVD. • JACKSONVILLE, FLORIDA 32256

TEL (904) 363-3417 • TOLL 1 (800) 642-2920 • FAX (904) 363-3408

Summary of Contents for ISOKERN Standard 36

Page 1: ...log appliance used in this product be installed in strict accordance with NFPA 58 NFPA 54 ANSI Z223 1 and the gas log manufacturer s explicit installation sizing and operation instructions It is the r...

Page 2: ...intenance Information 11 Warranty Note Illustrations shown in this manual are not to scale and are intended to show typical installations Nominal dimensions are given for design and framing reference...

Page 3: ...8 36 42 48 60 72 Standard Series 36 42 46 All units have either a 30 Finished opening height Standard Series or a 36 finished opening height Magnum Series The EM 40 chimney system is a single module r...

Page 4: ...31 19 3 4 60 1 4 28 1 2 WEIGHT 1040 lbs 1300 lbs 1420 lbs 1600 lbs 28 Model comes with three 3 sidewalls MAGNUM SERIES 60 72 28 28 38 38 69 3 4 57 1 4 85 1 2 73 1 2 85 3 4 85 3 4 69 55 1 2 65 1 2 81...

Page 5: ...A Base Plate B Side Wall B C D F E G H I C Back Wall D Damper Beam E Damper End F Smoke Dome G Top Sloping H Top Plate I EM40 Mono Block Number of Components May Vary with Different Kit Sizes Typical...

Page 6: ...uld also be considered Hint Before application wet down the surface area then apply water dipped firebrick for improved adherence All required through wall accesses gas and electrical line feeds and c...

Page 7: ...eel L support used in the masonry veneer around the front of the unit behind the veneer facing Any proposed brick stone or other masonry veneer facing must have sufficient foundation to support the fu...

Page 8: ...sided unit components by eliminating the back wall assembly In this installation the firebox side wall components are reversed so that the side wall taper sits to the outside of the box leaving the i...

Page 9: ...is activity must be avoided It is the responsibility of the building contractor to insure that the required dry in period is met and that the required lighting sequence is performed by the owner or by...

Page 10: ...he heating season Inspect the flue periodically during the heating season for the presence of soot and creosote build up If creosote or soot has accumulated it should be removed to reduce the risk of...

Page 11: ...Notes Maintenance Information 11...

Page 12: ...sion thereof is not responsible for any labor costs or indirect costs incurred for the replacement of defective components Earthcore is not responsible for misuse or mishandling of components Nothing...

Reviews: