INPUTS (CONT.)
TRANSFORM CV INPUT
Accepts 0-5 volts. Controls the
Transform
circuit.
This CV input is added to the
Transform
panel
control. Use the panel control to set the default
transformation from which you’d like to modulate.
This input has an inverting attenuator located
above the input jack. When the trimmer is fully
clockwise, the CV passes unchanged to be mixed
with the panel control. When the trimmer is at
noon, the CV is fully attenuated. When the trimmer
is fully counterclockwise, the CV is inverted
before mixing with the panel control to result in
subtraction.
Transform
can be modulated with
DC control voltages and audio signals.
SWITCHING THE
COMPLEX SOURCE
SWITCH TO
“MUTE” ALLOWS THE
TRANSFORM
CIRCUIT TO
ACT AS A HARMONIC GATE/VCA. VOLUME AND
HARMONIC COMPLEXITY INCREASES AS THE
CV INCREASES. THE EFFECTS ARE RELATIVE
TO THE SETTING OF THE PANEL CONTROL,
WITH THE SIGNAL MUTED WHEN THE PANEL
CONTROL IS FULLY COUNTERCLOCKWISE AND
NO VOLTAGE IS PRESENT AT THE CV INPUT.