Installation Guidelines 

(continued)

 

Heater

 

Wiring

 

Regardless

 

of

 

the

 

model

 

chosen,

 

there

 

are

 

5

 

wires

 

inside

 

the

 

base

 

of

 

the

 

heater

 

which

 

must

 

be

 

wired

 

correctly.

 

Three

 

wire

 

contacts

 

are

 

required

 

to

 

obtain

 

the

 

power

 

source.

  

The

 

wiring

 

code

 

is

 

the

 

same

 

for

 

120

 

volt

 

units.

  

 

The

 

heater

 

must

 

be

 

provided

 

disconnect

 

device

 

(switch/breaker)

 

from

 

the

 

supply

 

mains

 

having

 

a

 

contact

 

separation

 

in

 

all

 

poles

 

that

 

provide

 

full

 

disconnection

 

with

 

a

 

contact

 

separation

 

of

 

at

 

least

 

3

 

mm.

 

 

On

 

the

 

large

 

in

wall

 

unit

 

the

 

black

 

is

 

hot,

 

the

 

red

 

is

 

neutral,

 

and

 

the

 

green

 

is

 

ground.

 

On

 

the

 

small

 

in

wall

 

unit

 

the

 

black

 

is

 

hot,

 

the

 

blue

 

is

 

neutral

 

and

 

the

 

green

 

is

 

ground.

 

On

 

both

 

units

 

the

 

yellow

 

and

 

white

 

wires

 

go

 

directly

 

to

 

the

 

thermostat.

   

 

No

 

external

 

power

 

supply

 

is

 

needed.

  

Any

 

attempt

 

to

 

attach

 

an

 

external

 

power

 

supply

 

will

 

cause

 

damage

 

to

 

the

 

internal

 

components

 

and

 

will

 

result

 

in

 

product

 

failure.

   

 

When

 

connecting

 

multiple

 

units

 

to

 

a

 

single

 

thermostat,

 

the

 

units

 

must

 

be

 

connected

 

in

 

parallel

 

with

 

all

 

yellow

 

and

 

all

 

white

 

wire

 

leads

 

connected

 

to

 

their

 

same

 

respective

 

terminals

 

on

 

the

 

thermostat.

   

 

Failure

 

to

 

follow

 

these

 

guidelines

 

will

 

result

 

in

 

internal

 

transformer

 

failure

 

and

 

product

 

failure.

   

 

The

 

figures

 

below

 

depict

 

a

 

typical

 

wiring

 

procedure

 

using

 

conventional

 

12/2

 

wire

 

on

 

a

 

large

 

heater.

 

 

Thermostat

 

Wiring

 

Use

 

any

 

conventional

 

thermostat

 

or

 

doorbell

 

wire

 

to

 

route

 

the

 

thermostat

 

to

 

the

 

heater.

   

Unless

 

the

 

thermostat

 

is

 

diode

 

protected

 

or

 

voltage

 

sensitive

 

to

 

DC

 

(positive

 

and

 

negative),

 

it

 

doesn’t

 

matter

 

which

 

heater

 

thermostat

 

wire

 

goes

 

to

 

the

 

respective

 

contacts

 

on

 

the

 

back

 

of

 

thermostat.

   

 

Consult

 

the

 

wiring

 

instructions

 

that

 

are

 

included

 

with

 

the

 

thermostat

 

to

 

make

 

sure

 

that

 

the

 

low

 

voltage

 

thermostat

 

being

 

used

 

is

 

compatible

 

with

 

the

 

12

 

volt

 

DC

 

voltage

 

originating

 

from

 

the

 

yellow

 

and

 

white

 

thermostat

 

wires

 

from

 

the

 

heater.

   

The

 

thermostat

 

should

 

be

 

located

 

at

 

least

 

5

 

feet

 

from

 

the

 

location

 

of

 

the

 

in

wall

 

heater.

 

CZ

1000F

 

Existing

 

Construction

 

Installation

 

 

 
 
 
 
 
 
 
 
 
 

The

 

heater

 

cutout

 

should

 

have

 

a

 

minimal

 

size

 

of

  

16

 

1

/

2

 

(h)

 

x

 

12

 

3

/

4

 

(w).

 

 

 

 

Use

 

the

 

retrofit

 

brackets

 

as

 

shown.

 

Attach

 

the

 

heater

 

unit

 

to

 

the

 

wall,

 

6

 

ft.

   

(1.8

 

m)

 

or

 

higher

 

above

 

the

 

floor

 

to

 

the

 

bottom

 

of

 

the

 

heater

 

unit.

  

The

 

higher

 

the

 

better.

 

The

 

higher

 

location

 

of

 

the

 

heater

 

insures

 

that

 

obstacles

 

in

 

the

 

room

 

such

 

as

 

furniture

 

will

 

not

 

encumber

 

the

 

circulation

 

of

 

the

 

infrared

 

heat

 

waves

 

being

 

generated

 

from

 

the

 

heater.

 

This

 

assures

 

even

 

heat

 

distribution

 

and

 

prevents

 

cold

pockets

 

of

 

air.

 

Page 10 

Mounting Guidelines 

(CZ-1000F)

 

©2009 EarthWise Technologies, Inc 

OPTIMAL 
SITE 

OPTIONAL 
SITE 

Use

 

the

 

following

  

mounting

 

brackets

  

for

 

heater

 

installation

  

in

 

existing

 

construction.

 

Summary of Contents for CZ Infrared CZ-1000F

Page 1: ...ines User Information Guidelines Operating Instructions Warranty Servicing CZ Infrared by EarthWise Feel the Difference CZ Infrared Owner s Manual Therapeutic infrared heating systems for a green heal...

Page 2: ...by the Company Warranty Restriction This warranty is invalid if the factory applied serial number has been altered or removed from the product Warranty Claim Procedure To obtain warranty service you...

Page 3: ...ain product in good working order Limitations ALL WARRANTIES IMPLIED BY LAW INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY LIMITED TO THE DURATI...

Page 4: ...reen technology engineering affordable to purchase and economical to operate exceptionally economical extremely quiet they produce comfortable healthy therapeutic infrared heat They are easy to instal...

Page 5: ...ven with other electrically generated heating systems As much as 65 savings is achieved if replacing heating oil or other fossil fuel heating systems Quiet Operation CZ Infrared heating systems operat...

Page 6: ...he designer panel on the wall register can be left white or custom painted to match or contrast the walls Patented Proprietary Technology CZ Infrared heaters contain a proprietary high efficiency cera...

Page 7: ...with a minimum 3 inches of depth Heat Type Therapeutic far infrared heat Heat Chamber copper lined for maximum ion transfer Heating Elements Two 2 ceramic infrared emitters 500 w 500 w Ceramic Life Ex...

Page 8: ...to be installed Notes Calculate 4 6 hours of running time per day per heater installed to calculate Btu s and electrical energy cost Also remember that multiple unit installations in larger rooms can...

Page 9: ...uring the summer months Other than this there are no maintenance requirements involved In order to accomplish this the front plastic panel must be removed by removing the four screws and lifting up to...

Page 10: ...in the room such as furniture will not encumber the circulation of the infrared heat waves being generated from the heater This assures even heat distribution and prevents cold pockets of air OPTIMAL...

Page 11: ...es below depict a typical wiring procedure using conventional 12 2 wire on a large heater Thermostat Wiring Use any conventional thermostat or doorbell wire to route the thermostat to the heater Unles...

Page 12: ...ter This assures even heat distribution and prevents cold pockets of air Use the following mounting brackets for heater installation prior to sheetrock installation CZ 500F Existing Construction Insta...

Reviews: