Customer/Warranty Service: (800) 595-9605 

Page 15 

Do

 

not

 

place

 

objects

 

in

 

front

 

of

 

infrared

 

wall

 

units

 

that

 

have

 

been

 

mounted

 

lower

 

than

 

those

 

parameters

 

suggested

 

in

 

the

 

installation

 

instructions.

 

Doing

 

so

 

will

 

cause

 

the

 

unit

 

to

 

overheat,

 

which

 

will

 

trigger

 

the

 

high

 

temperature

 

limit

 

switch,

 

resulting

 

in

 

a

 

potential

 

service

 

call

 

to

 

reset/replace

 

the

 

switch.

 

For Your Safety/Warning 

For Best Performance 

It

 

is

 

recommended

 

that

 

the

 

air

 

flow

 

pattern

 

in

 

the

 

room

 

becomes

 

circular.

 

This

 

is

 

accomplished

 

by

 

mounting

 

the

 

heater

 

to

 

one

 

side

 

of

 

the

 

room,

 

as

 

per

 

the

 

illustration,

 

in

 

order

 

to

 

create

 

a

 

circular

 

flow

 

around

 

the

 

room.

  

 

Where

 

multiple

 

units

 

are

 

installed

 

in

 

larger

 

rooms,

 

this

 

circular

 

pattern

 

can

 

be

 

maintained

 

by

 

positioning

 

the

 

units

 

to

 

complement

 

the

 

air

 

flows.

 

This

 

is

 

accomplished

 

by

 

positioning

 

them

 

in

 

opposite

 

corners

 

of

 

the

 

room.

 

Operating Instructions 

The

 

units

 

are

 

self

regulating.

 

Temperature

 

is

 

controlled

 

via

 

a

 

low

voltage

 

thermostat

 

located

 

preferably

 

on

 

the

 

opposite

 

wall

 

from

 

the

 

heating

 

unit.

 

The

 

heater

 

fans

 

will

 

turn

 

on

 

when

 

the

 

power

 

to

 

the

 

infrared

 

heating

 

elements

 

turn

 

on.

 

After

 

the

 

heating

 

elements

 

have

 

come

 

up

 

to

 

full

 

temperature,

 

a

 

third

 

fan

 

will

 

turn

 

on

 

to

 

increase

 

the

 

airflow

 

into

 

the

 

room.

 

This

 

third

 

fan

 

will

 

remain

 

running

 

even

 

after

 

the

 

heating

 

elements

 

have

 

been

 

shut

 

down

 

by

 

the

 

thermostat,

 

in

 

order

 

to

 

distribute

 

the

 

remaining

 

heat

 

in

 

the

 

heating

 

elements

 

into

 

the

 

room.

 

 

Temperatures

 

can

 

be

 

regulated

 

from

 

a

 

central

 

control

 

(sold

 

separately)

 

or

 

the

 

heating

 

units

 

can

 

also

 

be

 

independently

 

turn

 

on

 

or

 

off

 

from

 

a

 

remote

 

location

 

via

 

a

 

central

 

on/

off

 

switch

 

for

 

each

 

unit.

 

The

 

switch

 

is

 

connected

 

between

 

the

 

low

voltage

 

thermostat

 

control

 

and

 

one

 

of

 

the

 

lead

 

wires

 

to

 

the

 

thermostat

 

from

 

the

 

thermostat

 

contact

 

on

 

the

 

heater.

 

Routinely

 

inspect

 

the

 

air

 

registers

 

on

 

the

 

infrared

 

unit

 

to

 

make

 

sure

 

that

 

there

 

is

 

no

 

dust

 

accumulation.

 

Vacuum

 

as

 

you

 

would

 

any

 

conventional

 

heat

 

or

 

air

 

conditioning

 

duct.

 

 

It

 

is

 

suggested

 

that

 

an

 

annual

 

dusting

 

of

 

the

 

ceramic

 

plates

 

be

 

performed

 

in

 

order

 

to

 

eliminate

 

any

 

residual

 

accumulation

 

of

 

dust

 

during

 

the

 

summer

 

months.

 

Other

 

than

 

this,

 

there

 

are

 

no

 

maintenance

 

requirements

 

involved.

 

In

 

order

 

to

 

accomplish

 

this,

 

the

 

front

 

plastic

 

panel

 

must

 

be

 

removed

 

by

 

removing

 

the

 

four

 

screws

 

and

 

lifting

 

up

 

to

 

release

 

the

 

panel

 

from

 

the

 

top

 

clip.

 

Maintenance 

©2009 EarthWise Technologies, Inc 

Page 8 

New

 

construction

 

(coldest

 

day

 

above

 

5

 

degrees),

  

standard

 

insulation,

 

one

 

window

 

per

 

room:

 

 

Room

 

size

 

below

 

250

 

sq.

 

feet:

 

1

 ‐ 

1000

 

watt

 

unit

 

Room

 

size

 

above

 

250+

 

to

 

500

 

sq.

 

feet:

 

2

 ‐ 

1000

 

watt

 

units

 

Room

 

size

 

above

 

500+

 

to

 

750

 

sq.

 

feet:

 

3

 ‐ 

1000

 

watt

 

units

 

Room

 

size

 

above

 

750+

 

to

 

1000

 

sq.

 

feet:

 

4

 ‐ 

1000

 

watt

 

units

 

Room

 

size

 

above

 

1000+

 

to

 

1250

 

sq.

 

feet:

 

5

 ‐ 

1000

 

watt

 

units

  

 

New

 

construction

 

(coldest

 

day

 

below

 

5

 

degrees)

  

&

 

all

 

remodels,

 

standard

 

insulation:

 

 

Room

 

size

 

below

 

200

 

sq.

 

feet:

 

1

 ‐ 

1000

 

watt

 

unit

 

Room

 

size

 

above

 

200+

 

to

 

400

 

sq.

 

feet:

 

2

 ‐ 

1000

 

watt

 

units

 

Room

 

size

 

above

 

400+

 

to

 

600

 

sq.

 

feet:

 

3

 ‐ 

1000

 

watt

 

units

 

Room

 

size

 

above

 

600+

 

to

 

800

 

sq.

 

feet:

 

4

 ‐ 

1000

 

watt

 

units

 

Room

 

size

 

above

 

800+

 

to

 

1000

 

sq.

 

feet:

 

5

 ‐ 

1000

 

watt

 

units

 

Room

 

size

 

above

 

1000+

 

to

 

1200

 

sq.

 

feet:

 

6

 ‐ 

1000

 

watt

 

units

 

 

Hallways

 

and

 

Nooks

:

 

1

 ‐ 

500

 

watt

 

unit

 

per

 

100

 

sq.

 

feet

 

Closets

 

and

 

Bathrooms

:

 

1

 ‐ 

500

 

watt

 

unit

 

per

 

100

 

sq.

 

feet

 

Installation

 

Instructions

 

for

 

1000

 

watt

 

unit

 

Required

 

outlet

 

opening

:

 

The

 

heater

 

cut

out

 

must

 

have

 

a

 

minimal

 

size

 

of

  

12.5

 

in.

 

W

 

x

 

16

 

in.

 

H

 

x

 

3.5

 

in.

 

D

 

in

 

order

 

to

 

accommodate

 

the

 

heater.

 

 

Mounting

 

the

 

Heater

 

The

 

heater

 

comes

 

with

 

two

 

sets

 

of

 

mounting

 

brackets.

  

Using

 

the

 

appropriate

 

set

 

of

 

brackets

 

for

 

the

 

mounting

 

conditions,

 

attach

 

the

 

heater

 

unit

 

to

 

the

 

wall

 

preferably

 

6

 

ft.

 

above

 

the

 

floor

 

to

 

eliminate

 

obstructions

 

to

 

air

 

flow.

     

The

 

heater

 

can

 

be

 

mounted

 

lower

 

if

 

preferred.

  

The

 

higher

 

location

 

of

 

the

 

heater

 

also

 

insures

 

that

 

obstacles

 

in

 

the

 

room

 

such

 

as

 

furniture

 

will

 

not

 

encumber

 

the

 

circulation

 

of

 

the

 

infrared

 

heat

 

waves

 

being

 

generated

 

from

 

the

 

heater.

  

This

 

assures

 

even

 

heat

 

distribution

 

and

 

prevents

 

cold

pockets

 

of

 

air.

  

The

 

infrared

 

heat

 

will

 

flow

 

evenly

 

from

 

floor

 

to

 

ceiling

 

so

 

the

 

location

 

of

 

the

 

heater

 

on

 

the

 

wall

 

is

 

not

 

pre

empted

 

by

 

normal

 

in

wall

 

heater

 

considerations.

 

 

Note:

  

Each

 

CZ

 

Infrared™

 

heater

 

comes

 

with

 

two

 

sets

 

of

 

mounting

 

brackets.

  

One

 

set

 

is

 

for

 

mounting

 

the

 

unit

 

prior

 

to

 

sheet

 

rock

 

installation,

 

and

 

the

 

second

 

set

 

is

 

for

 

mounting

 

the

 

unit

 

after

 

sheetrock

 

installation,

 

as

 

in

 

the

 

case

 

of

 

a

 

remodel.

 

Summary of Contents for CZ Infrared CZ-1000F

Page 1: ...ines User Information Guidelines Operating Instructions Warranty Servicing CZ Infrared by EarthWise Feel the Difference CZ Infrared Owner s Manual Therapeutic infrared heating systems for a green heal...

Page 2: ...by the Company Warranty Restriction This warranty is invalid if the factory applied serial number has been altered or removed from the product Warranty Claim Procedure To obtain warranty service you...

Page 3: ...ain product in good working order Limitations ALL WARRANTIES IMPLIED BY LAW INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY LIMITED TO THE DURATI...

Page 4: ...reen technology engineering affordable to purchase and economical to operate exceptionally economical extremely quiet they produce comfortable healthy therapeutic infrared heat They are easy to instal...

Page 5: ...ven with other electrically generated heating systems As much as 65 savings is achieved if replacing heating oil or other fossil fuel heating systems Quiet Operation CZ Infrared heating systems operat...

Page 6: ...he designer panel on the wall register can be left white or custom painted to match or contrast the walls Patented Proprietary Technology CZ Infrared heaters contain a proprietary high efficiency cera...

Page 7: ...with a minimum 3 inches of depth Heat Type Therapeutic far infrared heat Heat Chamber copper lined for maximum ion transfer Heating Elements Two 2 ceramic infrared emitters 500 w 500 w Ceramic Life Ex...

Page 8: ...to be installed Notes Calculate 4 6 hours of running time per day per heater installed to calculate Btu s and electrical energy cost Also remember that multiple unit installations in larger rooms can...

Page 9: ...uring the summer months Other than this there are no maintenance requirements involved In order to accomplish this the front plastic panel must be removed by removing the four screws and lifting up to...

Page 10: ...in the room such as furniture will not encumber the circulation of the infrared heat waves being generated from the heater This assures even heat distribution and prevents cold pockets of air OPTIMAL...

Page 11: ...es below depict a typical wiring procedure using conventional 12 2 wire on a large heater Thermostat Wiring Use any conventional thermostat or doorbell wire to route the thermostat to the heater Unles...

Page 12: ...ter This assures even heat distribution and prevents cold pockets of air Use the following mounting brackets for heater installation prior to sheetrock installation CZ 500F Existing Construction Insta...

Reviews: