background image

Easee AS
Professor Olav Hanssens vei 7A
4021 Stavanger, Norway

.easee-international.com

Summary of Contents for Base

Page 1: ...Installation guide Easee Base ...

Page 2: ...IMPORTANT Read carefully before use Keep for future reference You can find other languages available on our website easee support ...

Page 3: ...tions Safety instructions Common parts Adapter plate 1 Way 2 Way 3 Way 4 Way Power Rail Before connecting Ground connection plate Terminals Wiring Side panel Practical details 4 5 6 8 9 10 14 18 26 27 28 31 33 36 37 Table of contents ...

Page 4: ...to health up to and including life threatening injuries The Easee Base is a modular charging post for mounting up to four Easee Charging Robots With Easee Base it is possible to choose between four different configurations One way setup where only one charger is mounted 2 way setup with two chargers 3 way setup with three chargers and finally 4 way setup where there is a charger on all sides of th...

Page 5: ...ur Black IP degree IP44 Adapter plate for c c 160 mm2 foundation 45 degree rotation intervals using the adapter plate Screws and nuts included Connection via Power Rail Possibility of serial connection of posts In and out of the post Max 25 mm2 Up to the Charging Robots 6 mm2 General Features Electrical connection Cable size ...

Page 6: ...circuit is closed and must never be in direct contact or in contact with anything other than the plug in electronics Chargeberry Depending on the type of installation official authorisations may be required prior to installation Danger to life due to high electrical voltage Never make any changes to components or connecting cables Always have the prescribed maintenance installation and any repair ...

Page 7: ...hout knowledge of the product Make sure that children do not play with the product Do not use extension cords or unapproved adapters in combination with the product Even if the Charging Robot is designed to withstand normal weather conditions we recommend protecting it from direct sunlight or exposure to extreme weather conditions Do not use the product near strong electromagnetic fields or in the...

Page 8: ...8 Screws washers and nut x4 x4 x1 Column Side panel Adapter plate Power Rail Ground connection plate Common parts ...

Page 9: ...ion of the column to the adapter plate with 4 socket head screws Recommended torque is 30 40 Nm INFO It can be mounted in 45 increments to get the correct direction Column at a 45 angle A A A A A Common parts Adapter plate ...

Page 10: ...10 1 Way ...

Page 11: ...11 1 way blind cover 1 Way Parts Mounting plate x6 x4 Screws ...

Page 12: ...Attach mounting plate and blind cover to the column with 3 flat head screws each 6 screws total NOTICE Make sure the top end of the column is sealed with a plastic cap A A A A A 1 Way Plate and cover 1 A A ...

Page 13: ...13 Thread the cable through the hole in the column and the Easee charger backplate before attaching it with 4 rounded head screws B B B B B 1 Way Backplate 2 ...

Page 14: ...14 2 Way ...

Page 15: ...15 Mounting plates x6 x8 2 Way Parts Screws ...

Page 16: ...16 Attach the mounting plates to the column with 3 flat head screws each 6 screws total NOTICE Make sure the top end of the column is sealed with a plastic cap 2 Way Plates 1 A A A A A A A ...

Page 17: ...17 B B B B B B B B Thread the cables through each hole in the column and the Easee chargers backplates before attaching them with 4 rounded head screws 8 screws total 2 Way Backplates 2 B ...

Page 18: ...18 3 Way 4 Way ...

Page 19: ...19 3 Way 4 Way Parts x6 x20 Bottom frame Top plate Top frame 3 way blind cover Screws ...

Page 20: ...20 A Slide the bottom frame over the column and fasten it to the lower threaded hole with 1 flat head screw on each side 2 screws total 3 Way 4 Way Bottom frame 1 A ...

Page 21: ...21 A A Attach the top frame to the top two threads using 2 flat head screws on each side of the column 4 screws in total 3 Way 4 Way Top frame 2 A ...

Page 22: ...he top frame with the top plate and fix it with 4 rounded head screws NOTICE Make sure that all cables are pulled through the column holes 2 on each side before attaching the chargers backplates 3 Way 4 Way Top plate 3 B ...

Page 23: ... Easee chargers backplates to the sides perpendicular to the column openings with 4 rounded head screws each 8 screws total NOTICE Pull the cable through the hole in the backplates before attaching them 3 Way 4 Way First 2 chargers 4 B ...

Page 24: ...kplate to one of the open sides and close the other one with the blind cover Before attaching the blind cover the shielding tab must be flipped up in order to mount the blind cover plate with 4 rounded head screws 3 Way 3 Way Last charger and cover 5 B B B B B ...

Page 25: ...s backplates to the column with 4 rounded head screws each 8 screws total NOTICE Before installing the electronics in the backplates they must all be programmed please check the installation guide that came with the Charging Robots 4 Way 4 Way Last 2 chargers 5 B B B B B ...

Page 26: ...26 Power Rail ...

Page 27: ...ing system of the charging post which is described carefully in the following pages WARNING The Power Rail is a product to be installed by an authorized electrician and a declaration of conformity must always be provided upon completion by your installer WARNING Turn off the power before beginning the wiring Use extreme caution and follow instructions carefully ...

Page 28: ...he plate is essential for connecting the post to the protective earth PE Make sure the top PE terminal screw is open then wedge the end of the plate into the terminal from the back The ground connection plate should lie flat to the plastic housing 1 Power Rail Ground connection plate 1 ...

Page 29: ...rrated washer on the rod inside the column It should be placed between the metal column and the Power Rail Slide the Power Rail with the ground connection plate inside the column and latch the bottom of the rail into the catch ...

Page 30: ... washer on the rod NOTICE In order to complete the PE connection the grounding nut has to be fastened and the top PE terminal screw has to be tightened regardless of whether there is a wire in it or not Important Do not forget this step NB B NB 4 ...

Page 31: ...is lane is only used for PE connections We recommend using the two lower terminal sets for the main power cables One set of terminals is used for power in and the other is used for power out if you want to connect another charging post on the same cable Wire size up to 25mm Power in out Power Rail Terminals 2 PE lane ...

Page 32: ...es For a single charger only one set of terminals is used for two chargers both sets of terminals are used and for three or four chargers two wires have to share a terminal Wire size up to 6mm Charger 1 Charger 1 Chargers 1 2 Charger 2 Chargers 3 4 1 Way 2 Way 3 Way 4 Way ...

Page 33: ... grids Strip the cable cores by 12 mm If the cable has flexible conductors it is recommended to use cable end sleeves on all wires Tighten the screws with a torque of 5 Nm NOTICE Terminations should be visually and mechanically inspected before mounting the side panel Power Rail Wiring 3 1 2 PE 1 2 ...

Page 34: ...erefore the preferred grid type for charging electric vehicles NOTICE Depending on the time of installation and national standards the colours of the cables can vary from the illustration below Therefore please make sure that the conductors are correctly terminated before applying power NOTICE The charger is designed for a TN grid type with 5 lead cable TN 3 phase TN 1 phase ...

Page 35: ...ystems have no neutral connector and use only 4 conductors Therefore they can only provide 230 V across the phases NOTICE Depending on the time of installation and national standards the colours of the cables can vary from the illustration below Therefore please make sure that the conductors are correctly terminated before applying power IT TT 3 phase IT TT 1 phase ...

Page 36: ...36 After connecting all wires to the Power Rail it is time to mount the side panel with the 4 rounded head screws Power Rail Side panel 4 C C C C C ...

Page 37: ...ectly without the adapter plate in this case using a 80 x 80 center to center footprint For all the flat and rounded head screws we recommend 7 9 Nm of torque Contact your distributor or Easee Customer Support regarding the return and complaint of your product Download the latest manuals find answers to frequently asked questions and useful documents and videos for your product at easee support Fo...

Page 38: ...ng retrieving data or computer networks without the written permission of Easee AS Easee and all other Easee product names and slogans are trademarks or registered trademarks of Easee AS Easee products can be protected by one or more patents All other products and services mentioned may be trademarks or service marks of their respective owners Illustrations of the product and user interface are ex...

Page 39: ...39 ...

Page 40: ...Easee AS Professor Olav Hanssens vei 7A 4021 Stavanger Norway easee international com ...