25
8.3 Disassembly of the universal rod
①
Slacken and remove the screw bolts, 3 pieces, tightening the
sheet-metal to the plastic swinging arm with a plus screwdriver.
②
Remove the plastic cover, so you can separate the universal rod
form the winging arm.
③
Slacken and remove the screw bolt fixing the universal rod
to bearing block with a plus screwdriver and a shifting spanner.
④
Then the universal rod can be removed.
Tools:
a plus screwdriver, shifting spanner
8.4 Disassembly of the holder of knead ball
①
It is unnecessary to disassemble the massage mechanism to disassemble the holder of knead ball, just
disassemble the rear cover of the back rest.
②
Slacken the screw bolt tightening the holder to the swinging arm with a hexagonal socket wrench (10 mm) and
a shifting spanner. Pull the screw bolt out, and the holder can be removed.
③
Remove the tension spring and a new holder can be replaced if needed.
④
Proceed in the reverse order of disassembly when replacing a new one.
Tools
:
hexagonal socket wrench (10 mm), a shifting spanner
Slacken and remove the
screw bolts
The parts taken
down
Slacken the screw bolt
tightening the holder
The parts taken down
and the tools