Each ES-12 is configured as it leaves the factory, however, all parameters memory are backup by the
internal rechargable battery which can only last for 30 days after switched off. Therefore, if the DRO
have been powered off for more than 30 days, the ES-12 parameters might have to be reset or
reconfigured. Followings are the reset procedure for the ES-12.
A) Parameters Reset
Parameters Setup Procedure - System Reset
Operating Procedure :
1) Switch off the ES-12
2) Switch on the ES-12, after switching on, with the software version no " VER. X-? " showing in the message
window, press the number "8" key to enter the parameter reset function.
DRO proceeds a self
test on electronics
circuit after switched on
with the software number displayed on the message windoow, for example, "VER. M-3"
press to enter into the reset function
3) After entered in the reset function, ES-12 will process a "RAM TEST" to test all RAM memory, and also
reset all RAM memory to 0. Finally, resume all factory default setting.
4) Reset completed, the ES-12 will proceed LED display test until switch off.
DRO displays "RAM TEST"
means RAM test is in progress
DRO displays "RAM OK" means
RAM memory tested OK
DRO displays "RESET" means all parameters
have been resumed to factory default setting
Reset completed and ES-12 enters into a endless LED test to lest user know
if there is any missing segment in the LEDs, you can switched off the DRO
if you found no missing segment in the display LEDs
- B. 2 -
X
Y
Z
U
VER. X - ?
8888.8888
8888.8888
8888.8888
8888.8888
X
Y
Z
U
VER. M - 4
8888.8888
8888.8888
8888.8888
8888.8888
X
Y
Z
U
RAM TEST
8888.8888
8888.8888
8888.8888
8888.8888
X
Y
Z
U
RESET
8888.8888
8888.8888
8888.8888
8888.8888
X
Y
Z
U
EASSON...
ABS
8888.8888
8888.8888
8888.8888
8888.8888
X
Y
Z
U
RAM OK
8888.8888
8888.8888
8888.8888
8888.8888
Software version
Summary of Contents for ES-12
Page 8: ...1 Basic Fucntions Basic Functions BASIC...
Page 15: ...8 Built in Calculator Calculator...
Page 27: ...20 REF datum memory...
Page 31: ...24 LHOLE tool positioning for the Line Holes...
Page 35: ...28 INCL Inclined angle tool positioning...
Page 40: ...33 PCD tool positioning for Pitch Circle Diameter...
Page 45: ...R R R 38 tool positioning for ARC machining...
Page 63: ...R R R 56 Simplified R function...
Page 73: ...66 Shrinkage Calculation L L X 1 005...
Page 91: ...Parameter Setup B 1 SET UP...