background image

1. 208-240 volts may cause serious injury from electric shock. Disconnect
electrical power before starting installation or servicing. Leave power
disconnected until installation/service is completed.
2. Don’t roll or damage the power cord when install or move the machine
3. Don’t put finger or any other rod like object into the machine

1. Do not tilt the machine more than 45 ° in moving or installation to avoid
damage to the compressor.
2. Working temperature scope of the machine is 5

~ 38

.

3. The room temperature will go up around 3

from compressor heat

dissipation when dehumidifier running, it’s normal phenomenon, please feel free
to use.
4. It’s not necessary to use dehumidifier when the room temperature is below
10

, the absolute humidity is quite low at this condition.

5. Please try to seal environment better to increase the effect of dehumidifier.
6. Do not place the machine in the area which may come into contact with water
or chemical.
7. Do not use any relay, extension line or adapter to connect the power of
machine.
8. Do not place the machine next to the stove, heater and other equipment will
dissipate heat, and area with direct sunlight or wind and rain.
9. Do place the plug stably and clean the dust on power line.
10. Do not damage or modify the power line, do not repair by yourself and
disassemble or modify the machine.
11. Do place the drainage tube smoothly for continuously drain.
12.Shutdown the equipment and cut power when in malfunction.

— 1 —

WARNING

CAUTION

SAFTY INSTRUCTIONS

Summary of Contents for SDD-168L

Page 1: ...DEHUMIDIFIER SDD 168L INSTRUCTION MANUAL...

Page 2: ...SAFTY INSTRUCTIONS 1 SPECIFICATIONS 2 UNPACKING THE DEHUMIDIFIER 3 INSTALLATION GUIDE 4 OPERATION GUIDE 6 STRUCTURE AND RUNNING 7 OVERALL PARTS 8 NORMAL MALFUNCTION REMOVAL 9 DIRECTORY...

Page 3: ...not necessary to use dehumidifier when the room temperature is below 10 the absolute humidity is quite low at this condition 5 Please try to seal environment better to increase the effect of dehumidif...

Page 4: ...nge RH40 RH95 MECHANICAL Weight 220 lbs without packaging Drain Size 39 5 x 20 6 Capacity 355 Pints 86 F 80 RH Airflow 1060 CFM free flow ELECTRICAL Voltage 208 230 VAC 1 60 HZ Operating Current 12 5A...

Page 5: ...Automatic defrost protection function The dehumidifier will defrost automatically when freezing occurs The dehumidifier will start automatically when defrost process is complete Default defrost setti...

Page 6: ...ng to the position of install hole on the machine then install the expansion screw to fix the thread rod B Install the machine through the four thread rods and adjust the height according the space to...

Page 7: ...to fix the dehumidifier on the ceiling 3 Ensure the installation of dehumidifier is horizontal to avoid malfunction or leakage 4 Ensure drain tube is installed unhindered without overmuch bends 5 Ens...

Page 8: ...d with a little diluted neutral detergent 3 Filter Cleaning it will affect the dehumidifying effect or cause malfunction if accumulate dust on filter it needs to be cleaned regularly clean it at least...

Page 9: ...ith 1 RH scale in running mode Press the key to set the hour or minute down with 1 hour or 1 minute scale in timed on off or clock setting mode 5 Humi Press the key to set the humidity value down with...

Page 10: ...Heat exchanger 13 Base bracket 4 Heat exchanger cover 14 Power cord pressing block 5 Top plate 15 Electrical box 6 High pressure pipe 16 Main control board 7 Low pressure pipe 17 Connection terminal 8...

Page 11: ...2 POWER OFF 3 POWER IS NOT PLUG IN 4 BLOWN FUSE 1 RESUME POWER 2 POWER ON 3 PLUG IN 4 REPLACE FUSE BAD DEHUMIDIFICATION EFFECT 1 FILTER BLOCKED WITH DUST 2 AIR INLET IS BLOCKED 3 USED IN BAD SEALED RO...

Page 12: ...EAST dehumidifier manufacturer Room 1603 1604 Yifeng Times Mansion Hangzhou China 311113 Phone 8613685770742 WhatsApp 8613685770742 Skype tiger19840517 https www eastdehumidifier com...

Reviews: