background image

PREPARING BEFORE INSTALLATION

A. Cut off all the electrical to ensure the safety

B. Make sure the power and drain tunnel

C. Prepare necessary tools like screwdriver, thread rod, spanner etc.

START INSTALLATION

A. Drill four fixing holes on the ceiling according to the position of install

hole on the machine, then install the expansion screw to fix the thread rod.

B. Install the machine through the four thread rods, and adjust the height

according the space to ensure the machine on horizontal level.

C. Connect the drain tube to make sure no leakage, no block for the

drainage.

Connect the power, please make sure the power supply is 208~240v/60hz

and have overload protection.

— 4—

INSTALLATION GUIDE

TO

P

VIE

W

SID

E

VIE

W

Summary of Contents for SDD-26L

Page 1: ...DEHUMIDIFIER SDD 26L INSTRUCTION MANUAL...

Page 2: ...SAFTY INSTRUCTIONS 1 SPECIFICATIONS 2 UNPACKING THE DEHUMIDIFIER 3 INSTALLATION GUIDE 4 OPERATION GUIDE 6 STRUCTURE AND RUNNING 7 OVERALL PARTS 8 NORMAL MALFUNCTION REMOVAL 9 DIRECTORY...

Page 3: ...not necessary to use dehumidifier when the room temperature is below 10 the absolute humidity is quite low at this condition 5 Please try to seal environment better to increase the effect of dehumidif...

Page 4: ...ity Range RH40 RH95 MECHANICAL Weight 35 lbs without packaging Drain Size 5 8 Capacity 55 Pints 86 F 80 RH Airflow 150 CFM free flow ELECTRICAL Voltage 208 230 VAC 1 60 HZ Operating Current 2 5A 86 F...

Page 5: ...Automatic defrost protection function The dehumidifier will defrost automatically when freezing occurs The dehumidifier will start automatically when defrost process is complete Default defrost setti...

Page 6: ...ng to the position of install hole on the machine then install the expansion screw to fix the thread rod B Install the machine through the four thread rods and adjust the height according the space to...

Page 7: ...to fix the dehumidifier on the ceiling 3 Ensure the installation of dehumidifier is horizontal to avoid malfunction or leakage 4 Ensure drain tube is installed unhindered without overmuch bends 5 Ens...

Page 8: ...d with a little diluted neutral detergent 3 Filter Cleaning it will affect the dehumidifying effect or cause malfunction if accumulate dust on filter it needs to be cleaned regularly clean it at least...

Page 9: ...ith 1 RH scale in running mode Press the key to set the hour or minute down with 1 hour or 1 minute scale in timed on off or clock setting mode 5 Humi Press the key to set the humidity value down with...

Page 10: ...Heat exchanger 13 Base bracket 4 Heat exchanger cover 14 Power cord pressing block 5 Top plate 15 Electrical box 6 High pressure pipe 16 Main control board 7 Low pressure pipe 17 Connection terminal 8...

Page 11: ...2 POWER OFF 3 POWER IS NOT PLUG IN 4 BLOWN FUSE 1 RESUME POWER 2 POWER ON 3 PLUG IN 4 REPLACE FUSE BAD DEHUMIDIFICATION EFFECT 1 FILTER BLOCKED WITH DUST 2 AIR INLET IS BLOCKED 3 USED IN BAD SEALED RO...

Page 12: ...EAST dehumidifier manufacturer Room 1603 1604 Yifeng Times Mansion Hangzhou China 311113 Phone 8613685770742 WhatsApp 8613685770742 Skype tiger19840517 https www eastdehumidifier com...