background image

Doc.No.:EM1701A190416 

Version No.: V1.0020190416(E) 

Date: 2019-9-23 

Operating Instructions 

D-Drive EM-1701A-C10 Electronic Combination Controller 

l

 

This manual is used for SafeLogic C10 D-Drive EM-1701A-C10 EntryPad used in conjunction 
with DL-1701 D-Drive DeadBolt Lock Body. 

l

 

 

 

ATTENTIONS: 

l

 

For indoor use only. 

l

 

Battery Low Voltage: 

The entrypad will alert low battery, when battery voltage is low. 

PLEASE 

REPLACE THE BATTERY IMMEDIATELY. MAKE SURE A 9V ALKALINE BATTERY 
IS USED.

 

l

 

Install the 9V ALKALINE battery in the back of the EntryPad. Refer to the instructions of 
“Replace the battery”. 

l

 

For Mounting and wiring, please refer to the installation instruction. 

 

FEATURES: 

1.

 

10 User Codes Capacity 

a.

 

Recovery code: 

Resets controller back to manufacturer’s default settings. Can’t open lock. 

Recovery Code must be changed from default. 

b.

 

Super Code (ID0): 

Open lock, set functions, and manage Manager Code. Manufacturer default 

super code is 1-1-1-1-1-1. 

c.

 

Manager Code (ID1): 

Open lock and manage user code(s). Manufacturer default super code is 

1-2-3-4-5-6. 

d.

 

User Code (ID2~9): 

Opens lock. No default user code(s) and can be added. 

 

2.

 

Wrong Entry Penalty 

Entry of four (4) consecutive invalid codes results in a 5-minute penalty time period.

 

a.

 

The unit beeps at 5 second intervals indicating that it is still in the penalty time period.

 

b.

 

While the system is in the penalty time, the entrypad buttons remain unresponsive. Pressing 
buttons during penalty will not restart or lengthen the penalty time period. It will continue to 
count through the 5 minute penalty time period. 

 

c.

 

While the system is in penalty time, removal of the battery will not interrupt the penalty time 
countdown. Upon reinstallation of the battery, the entrypad continues to count down until the 5 
minute penalty time expires. 

 

 

Summary of Contents for EM-1701A-C10

Page 1: ...k Recovery Code must be changed from default b Super Code ID0 Open lock set functions and manage Manager Code Manufacturer default super code is 1 1 1 1 1 1 c Manager Code ID1 Open lock and manage user code s Manufacturer default super code is 1 2 3 4 5 6 d User Code ID2 9 Opens lock No default user code s and can be added 2 Wrong Entry Penalty Entry of four 4 consecutive invalid codes results in ...

Page 2: ...ngle and Dual User Mode a Single Mode Open lock with one 1 code b Dual Mode Open lock with two 2 codes manager and user code 7 Time Delay and Time Window a Time Delay A time period of waiting for the lock to open The maximum Time Delay is forty 40 minutes b Time Window A time period for entering the code s to open lock after Time Delay The maximum Time Window is twenty 20 minutes USER OPERATING IN...

Page 3: ...n the last digit of this code until one beep sounds followed by two beeps b Press button 1 One beep sounds indicating that the system is ready to receive the new Manager Code c Enter a desired six 6 digit code once One beep sounds indicating that the entry is valid d Repeat the six digit code One beep will sound indicating that the six digit codes entered were the same and the addition of the mana...

Page 4: ...at the disabling user is successful d Enter the disabled user code to make sure the code is disabled 7 Enable Manager a Enter the super code and hold down last digit of code until one beep sounds followed by two beeps b Press button 1 one beep will sound indicating the enabling manager is successful 8 Enable User a Enter the manager code and hold down last digit of code until one beep sounds follo...

Page 5: ...tes codes the manager code and user code will be both deleted and single user mode is set d In Dual User Mode super code disables enables manager code and user code at the same time 12 Disable Dual User Mode a Enter the super code and hold down last digit of code until two beeps sounds b Press button 0 to set controller to single user mode 13 Set Change Time Delay Time Window Mode a Enter the supe...

Page 6: ...od indicating the start of the Time Window period Two beeps sound every ten 10 seconds during Time Window period e Enter both user and manager codes to unlock Note a When unlocking by super code the controller is unlocked without time delay and time window b During the time window if the code is not entered the controller will be locked after time window period with four beeps sound c Press button...

Page 7: ...reset button for more than 3 seconds then reconnect the cable one beep will sound release the reset button d The controller has been reset back to manufacture s default Note If no beep sound Repeat steps a through c 2 Reset the lock to connect with a new entrypad a Remove the entrypad b Press the reset button with a pin for about 2 or 3 times c Connect a new entrypad with the lock d Three beeps wi...