background image

SOLAR OFF-GRID MPPT PCU, PAGE 16, Ver. 1.0

Warranty 

Card

Eastman warrants to the original purchaser provided the product is still in possession 
and  used  by  original  purchaser,  from  the  date  of  shipment  from  the  company. 
Consumer shall have no coverage or benefit under this warranty in the event of any of 
the following conditions are applicable. 

1. The product has been subjected to abnormal use or conditions, improper storage, 

exposure to excessive moisture or dampness, exposure to excessive temperature, 
unauthorized modification, unauthorized repair (including but not limited to the use of 
unauthorized spare parts in repairs), abuse, accident, act of God, spill of food or 
liquid, improper installation and breakage or damage. 

2. The consumer has not notified the defect of the product to the company during the 

warranty period. 

3. The product Serial No. code or the accessory code has been removed, defaced or 

altered. 

4.

 

The seals are broken or show evidence of tampering. 

5. All plastic surfaces and all other externally exposed parts that are scratched or 

damaged due to abnormal customer use. 

This warranty is offsite in nature, the consumer will have to take the product to the 
company or it's authorised service centers for repair and will have to take it back at 
his/her own expenses. 

No other express warranty is applicable to this product. The duration of any implied 
warranties,  including  the  implied  warranty  of  marketability  or  fitness  for  particular 
purpose or use is limited to the duration of express warranty herein. The company shall 
not  be  liable  for  the  loss  of  use  of  the  product  inconvenience,  loss  or  any  other 
consequent damage arising out of the use or inability of use, of this product or for the 
breach of any express or implied warranty including the implied warranty of market 
ability or merchantability or fitness applicable to this product. All disputes are subject to 
Delhi jurisdiction only. 

Model No : 
Serial No :  
Name of Purchaser :
Address :

Date of Purchase : 
Dealer's Name :

Summary of Contents for ESM3K/48

Page 1: ...CORPORATE OFFICE EASTMAN AUTO POWER LTD 547 Udyog Vihar Phase V Gurgaon 122016 Haryana India India Toll Free No 1800 419 8610 91 124 4682600 2610 sales eastmanglobal com...

Page 2: ...nfigurable parameters through front end wide screen LCD display Intelligent mixing of Grid current with solar in case of solar energy shortfall during cloudy days Highest efficiency in its class Built...

Page 3: ...ntries and a 2200 loyal distributor and dealer network across the world Eastman Auto Power Limited instituted by Eastman group is a leading manufacturer of Tall Tubular Batteries Tubular Gel SMF Batte...

Page 4: ...Instruction D Storage Instructions 03 04 Know Your Off Grid MPPT PCU Operating Instructions A PCU System Description B Front Panel Description C Back Panel Description D Wiring Diagram E How To Confi...

Page 5: ...ation maintenance repair of the equipment should be undertaken by trained experiencedandauthorizedserviceorelectricalpersonnel 5 To disconnect turn off all MCBs located at the back panel of PCU We req...

Page 6: ...water or excessive humidity Routine preventive check should be carried out Store the Solar PCU in its original packing keeping the arrow on the box pointing vertically upward Store it in dry location...

Page 7: ...U please carry out visual check for any damage during transport B PCU Installation Guide The system must be installed in a dry clean room To have proper ventilation the user must ensure enough air exc...

Page 8: ...MCB for battery voltage 96V Press Soft start switch for 30 sec to charge the capacitor before switching ON the battery MCB Solar Charging will start Press the Reset Switch to PCU ON Thereafter switch...

Page 9: ...oard It controls operation of MPPT charger and PCU It contains power modules of MPPT and PCU MPPT receives DC supply from solar array and provides charging voltage to battery and DC voltage for PCU op...

Page 10: ...ation Display Display Parameter Battery 57 9V 0 0A 1 0A 15 31 50 Dischg 0 9KWH 0 5KWH Output 220V 15 31 50 50Hz 0 0A 100W 0 9KWH View 1 View 2 Solar 140V 15 31 50 0 0A 0 0W 0 8 KWH Grid 220V 15 31 50...

Page 11: ...tral Battery Mains MCB For Load Distribution Solar Panel Junction Box IP65 blocking diode MCB Fuse ATC BYPASS 2 INVERTER UPS 1 0 PANEL SPV BATT GRID O P 7 5KVA 120V 10KVA 120V SOFT START SWITCH FUSE B...

Page 12: ...Volt Reset All The Set Values to Default Values Reset All Setting Inv output setting Set voltage as per suitable season Freedom to connect any kind of batteries Choose When to Cut Solar Reset All Grid...

Page 13: ...Solar Grid If Otherwise CASE 01 Grid Supply Solar Power Load Battery Backup Solar PCU Solar Absent Grid Present A Load Runs on Battery If Batt volt 11 5V B Load Runs on Grid Battery Charging By Grid...

Page 14: ...n Grid Battery Charging By Solar If Otherwise CASE 01 Grid Supply Solar Power Load Battery Backup Solar PCU Solar Absent Grid Present A Load Runs on Grid If Batt volt 11 2V B Load Runs on Grid Battery...

Page 15: ...r Load Battery Backup Solar PCU Solar Absent Grid Present A Load Runs on Grid B Battery Charging By Grid CASE 02 Grid Supply Solar Power Load Battery Backup Solar PCU Solar Absent Grid Absent A Load R...

Page 16: ...ch at OFF position Ensure battery voltage and polarity Switch ON Battery MCB Ensure SOLAR PV Module voltage polarity Connect solar PV Module supply Now turn ON PCU Reset switch While connecting Grid s...

Page 17: ...uidelines 1 Ensure proper ventilation and cleanliness surrounding your PCU 2 We recommend to keep Room Temperature at about 30 C 5 C for improved life cycle of the batteries Checkpoints Check points Q...

Page 18: ...Contact Our Service Center f Maintain ambient temp as per spec Output Under Over Voltage a Output short circuit b Control board failed a Check load b To reset the fault press reset switch on front LCD...

Page 19: ...verse Protection Reverse Current Flow High Temperature Over Current Battery Overcharge Protection Pv Reverse Protection Reverse Current Flow High Temperature Over Current Battery Overcharge Protection...

Page 20: ...faced or altered 4 The seals are broken or show evidence of tampering 5 All plastic surfaces and all other externally exposed parts that are scratched or damaged due to abnormal customer use This warr...

Reviews: