REQUIRED TOOLS
(2) - Pipe wrenches which open to at least 1-1/2"
(1) - Adjustable wrench which opens to at least 1"
(1) - Teflon tape or Pipe dope
INSTRUCTIONS for WATER TANK MODEL & NEVERCOLD
™
PUMP INSTALLATION
PUMP INSTALLATION
WARNING:
WARNING: For Indoor Use Only.
WARNING:
WARNING: Do not plug the pump in until the installation is complete.
1. Shut off the cold water supply to the water heater. This may be on the cold supply
line above the tank or located where the water line enters the residence.
2. Open a hot water faucet in the residence and allow the water to run until it stops.
Leave the faucet open until the installation has been completed.
3. Remove the hot water line from the hot water heater at the threaded outlet pipe at
the top of the tank.
4. Place the large union nut over the threaded outlet pipe before threading the 3/4"
NPT Tail Piece onto the threaded outlet pipe. (Fig. 1.)
5. Place the union gasket on the tail piece and thread the large union nut onto the
circulator. (Fig. 2.)
6. Reconnect the hot water line that was removed in step 3 to the circulator. (Fig. 3.)
Use pipe dope or Teflon Tape to seal the threads. If flex hoses are used at this
connection, then NO pipe dope or Teflon Tape is required.
7. Reopen the cold water supply valve to the hot water heater. Allow the water to run
at the faucet to purge the air from the lines. Close the faucet.
8. Plug in the circulator into a properly grounded 115V outlet.
2