6.2 Service and Adjustment of Control Unit (Cont.)
15. Reassemble the control unit, using the following steps. Slide (2) hose clamps
onto each control tube. Slide one end onto a barbed nipple in the control
housing, and the other end on the barbed nipple directly across from first
nipple. MAKE SURE HOSE CLAMP BOLTS ARE ON THE SIDE
CLOSEST TO THE CENTER OF HOUSING. Repeat for other control
tube. Slide clamps to end of each tube and tighten securely with 5/16” socket
wrench with extension.
Note: picture shown without cylinder assembly for better viewing.
DO NOT remove cylinder assembly.
16. Slide pincher plate onto cylinder shaft and attach with the shaft nut, making
sure pincher bars are directly centered over the control tubes. (Use a flat
blade screwdriver or wrench to extend the cylinder shaft for ease of
assembly).