10
Eastwood Technical Assistance: 800.343.9353 >> tech@eastwood.com
MENU SELECTIONS
The Microprocessor offers many display parameters to monitor major compressor functions and maintenance data including cumulative run time recording.
Whenever any of the Control Panel keys are pressed, the Display Panel illumination feature will activate and, if not touched within 1 minute, will automatically go out.
TO BEGIN DISPLAY SEQUENCE:
• Press 1st time:
Displays: Motor amperage draw for each individual 3-phase leg
(FIG 12)
• Press 2nd time:
Displays: Eastwood Tech Phone #
(FIG 13)
• Press 1st time:
Displays: Air Pressure
(FIG 14)
(Air pressure at Scroll output, may read higher than Gauge Pressure visible at the side of the unit)
• Press 2nd time:
Displays: Scroll Air Temperature
(FIG 15)
• Press Again:
Toggles between Air Pressure and Air Temperature.
• Press
Displays: RUN PARAMETER
(FIG 16)
• Press Again:
Displays: Returns to motor amperage draw for each individual 3-phase leg:
(FIG 12)
• Press
Displays: TOTAL RUN TIME
(FIG 17)
(Records total overall unit running time)
• Press
Displays: TOTAL LOAD TIME
(FIG 18)
(Records actual Scroll/Motor running time under load)
• Press
Displays: OIL FILTER TIME
(FIG 19)
(Cumulative time of oil filtration)
• Press
Displays: OIL/AIR FILTER TIME
(FIG 20)
(Cumulative time of moisture/oil separator filter)
• Press
Displays: AIR FILTER TIME
(FIG 21)
(Cumulative time of air filtration)
▼
▲
▼
▲
▼
▼
▼
▼
▼
▼
▼
▼
FIG. 12
FIG. 13
FIG. 14
FIG. 15
FIG. 16
FIG. 17
FIG. 18
FIG. 19
FIG. 20
FIG. 21
FIG. 12