16
Eastwood Technical Assistance: 800.343.9353 >> tech@eastwood.com
PANEL REMOVAL
Access to all interior components is by panel removal. All four sides and top panels
are removable:
1.
Front rear and side panels are removed by placing the included triangular
profile Panel Key over the triangular posts of the latches
(FIG 1)
. Front and
rear panels have 2 latches each and are released by turning the key 1/4 of
a turn to the respective outside corner. End panels have one latch each and
are released with 1/4 turn to the right.
2.
After latch release, lift panel off locating pins on the outer floor of the unit
then pull up and away
(FIG 2)
.
3.
The top panel is removed by inserting a 5mm hex key into the holes at the
corners and loosening the socket head cap screws.
NOTE:
Do not remove the screws as the underside flange of the top panel
has Keyhole” slots. Standing at the rear of the Compressor, slide the top
panel to the right to clear screw heads and lift off
(FIGS 3 & 4)
.
OIL CHANGE
1.
Shut off power. Press the “OFF” Button and shut off main power.
2.
Release all pressure from the Tank and Compressor.
3.
Remove the Oil Fill Plug from the upper side of the Oil Reservoir with a
22mm wrench (not included)
(FIG 35)
.
4.
Unroll the transparent Oil Drain Tube and place the open end into a suitable
container
(FIG 36)
.
5.
Open the Oil Drain Ball Valve by rotating the handle 1/4 turn Counter
Clockwise.
6.
Allow oil to drain into vessel.
7.
Close Oil Drain Ball Valve by rotating the handle 1/4 turn Clockwise
8.
Add 74 oz. [2.2 liter] of Eastwood #31718 Scroll Compressor Oil to the fill
port of the Oil Reservoir using a suitable funnel (not included).
9.
After the recommended amount of Oil is added, view the Sight Gauge on
the side of the Oil Reservoir to make sure that it reads FULL (At or above
the “M” Line but not above the “H” Line
(FIG 35)
. If the oil level is below
the “M” Line, oil must be added.
10.
Replace Oil Fill Plug and tighten securely.
11.
Restore power to Compressor. Depress the
“START”
Button ,
run Compressor and check for leaks.
12.
Press the
“OFF”
Button and replace all panels.
Used Oil is a polluting material and should be disposed of in
compliance with local regulations.
FIG. 35
FIG. 36
H
M
L
Oil
Fill
✓
✓
✓
✓
PERFORM THE FOLLOWING STEPS BEFORE PERFORMING
ANY MAINTENANCE PROCEDURES!
•
Shut off power. Press the “OFF” Button [B] (Fig 9)
and shut off the main 3 phase power switch to the unit.
•
Release all pressure from the Tank and Compressor.