FRONT PANEL FEATURES (FIG 1)

DIGITAL TEMPERATURE DISPLAY:

 Displays Tank temperature in °F

DIGITAL TIME DISPLAY:

 Counts down cleaning time in minutes and seconds.

HEAT BUTTON:

 Switches 

Tank Heat

 only ON or OFF.

+

 TEMPERATURE KEY:

 Raises Tank Heat Temperature.

-

 TEMPERATURE KEY:

 Lowers Tank Heat Temperature.

DEGAS BUTTON:

 Degasses aerated fresh cleaning solution. 

SOFT BUTTON:

 Reduced 60% power setting for delicate cleaning. 

NORMAL BUTTON:

 Full 100% power setting for normal cleaning. 

+

 TIME KEY:

 Increases cleaning time.

-

 TIME KEY:

 Decreases cleaning time. 

FIG. 1

FIG. 1

FIG. 2

FIG. 2

REAR PANEL FEATURES (FIG 2)

Main Power Switch:

 Switches Ultrasonic Cleaner main power On or Off (Up = ON, Down = OFF). 

Power Cord Receptacle:

 Accepts female end of supplied Power Cord.

Cooling Vents:

 Exhaust air for cooling fan (Intake is at underside of unit).

Summary of Contents for 33968

Page 1: ...ULTRASONIC CLEANERS INSTRUCTIONS Items 33968 33969...

Page 2: ...g 99 Minutes Maximum Power Usage 33968 150 Watts Ultrasonic Clean only 450 Watts with Heat 33969 200 Watts Ultrasonic Clean only 500 Watts with Heat Operating Frequency 40 kHz Tank Size 33968 11 8 300...

Page 3: ...ons can cause you to lose control 2 ELECTRICAL SAFETY a Power tool plugs must match the outlet Never modify the plug in any way Do not use any adapter plugs with earthed grounded power tools Unmodifie...

Page 4: ...s can reduce dust related hazards 4 POWER TOOL USE AND CARE a Do not force the power tool Use the correct power tool for your application The correct power tool will do the job better and safer at the...

Page 5: ...luid depth is 2 75 7cm DO NOT attempt to move the Ultrasonic Cleaner while full Always drain the Ultrasonic Cleaner before moving DO NOT place the Ultrasonic Cleaner on a soft surface where the coolin...

Page 6: ...fill line with a full load of parts included BURN HAZARD Use caution when adding or removing items from the cleaning tank as the fluid is likely to be hot DO NOT drop any item into the tank as this ma...

Page 7: ...Tank Heat Temperature DEGAS BUTTON Degasses aerated fresh cleaning solution SOFT BUTTON Reduced 60 power setting for delicate cleaning NORMAL BUTTON Full 100 power setting for normal cleaning TIME KEY...

Page 8: ...o touch as this will greatly reduce the cleaning action Lower the Basket into the Tank area FIG 3 FIG 3 FIG 3 FIG 4 FIG 4 FIRE OR EXPLOSION HAZARD DO NOT use solvent based or flam mable cleaning agent...

Page 9: ...mode is selected SET TEMPERATURE Raise Temperature o Press Temperature Key once and release to increase temperature by 1 F o Hold Temperature Key in to increase temperature by 10 F increments Lower T...

Page 10: ...it has cooled to a safe level When cooled sufficiently set the Unit Power Switch to OFF Grasp the Basket by the handles and slowly remove it allowing excess fluid to drain into the Tank DRAIN TANK Un...

Page 11: ...s touching in the Basket area re ducing the cleaning effectiveness Reduce the quantity of parts in Basket Move parts away from one another increasing the space between them Cleaning solution may be ex...