PROBLEM
CAUSE
CORRECTION
Does Not Run
When Switch
is Turned On
No Power
Check 120 VAC input plug connection.
Tripped Circuit
Breaker
The Contour SCT operates on a 15 Amp minimum
circuit, 20 Amp is strongly recommended.
Motor Runs
Too Slowly/
Develops Low
Power
Undersized
and/or too long
of an extension
cord used.
Use only 16 Gauge or larger cord and limit length
to 25’.
Excessive
Noise and
Vibration
Drum is Likely
Damaged
WARNING: This is an extremely unsafe condition!
Discontinue use and replace Drum!
Motor
Overheats
Excessive
Pressure Being
Applied
Allow Contour SCT to cut by rotation alone.
Do not force.
Dirt and
Cutting Debris
Buildup in
Motor Cooling
Air Slots.
Use a brush or compressed air to remove debris.
Can't Loosen
Abrasive Drum
Retaining
Screw
Retaining
Screw Uses A
Left-Handed
Thread
Turn Retaining Screw clockwise to remove.
See "DRUM REPLACEMENT" for additional
information.