14
Eastwood Technical Assistance: 800.343.9353 >> tech@eastwood.com
TROUBLESHOOTING
PROBLEM
CAUSE
CORRECTION
Unit is Leaking
Oil at Fitting(s)
Loose Fitting.
Tightening fitting resolves most issues.
Rust in Water
When Draining
Tank
Compressors are designed to accumu-
late moisture in the air tank instead of in
your air stream.
We recommend draining air tank weekly to remove moisture. It is not uncom-
mon to have brown/rust colored water in tank as the inside of the tank is bare
steel to eliminate any coating delamination. This will ultimately disappear as a
film of oil will coat inside of tank during use (see page 9).
Unit Will Not
Reach 145 PSI,
Shuts Off Early
Defective Pressure gauge.
Replace pressure gauge with known good gauge and retest unit. If gauge is
accurate replace Pressure Switch #32207.
Defective Pressure Switch
(On/Off switch).
Replace Pressure Switch #32207.
Sludge in Oil
Tank and On
Dipstick
Light, intermittent use, operation
in warm, damp locations, or during
high humidity weather conditions will
contribute to the formation of excess
condensation in the system.
Drain and replace oil with 2 qts #31718 Eastwood Scroll Compressor Oil.
Replace Oil Filter #31715.
Replace Moisture Filter #31716.