background image

5

coMPoNENt idENtiFicAtioN

cAUtioN

missing or illegible labels must be replaced, contact Precision 
medical, inc..

P

ressure

 g

auge

A

ir

 o

utlet

F

itting

R

egulator

 K

nob

S

uction

 F

eet

F

ilter

 e

ndcap

P

ower

 c

ord

o

n

 / o

ff

 S

witch

A

ir

 F

ilter

 A

ssembly

P

ower

 c

ord

 K

eeper

Summary of Contents for PM50

Page 1: ...0 save these instructions CAUTION Federal USA law restricts this device to sale by or on the order of a physician 300 Held Drive Tel 001 610 262 6090 Northampton PA 18067 USA Fax 001 610 262 6080 www...

Page 2: ...E USING 2 Explanation of Abbreviations 2 SAFETY Information Warnings and Cautions 2 SPECIFICATIONS 4 COMPONENT IDENTIFICATION 5 GROUNDING INSTRUCTIONS 6 OPERATING INSTRUCTIONS 6 Cleaning maintenance 7...

Page 3: ...d this manual DO NOT USE the Compressor and contact your Equipment Provider Explanation of Abbreviations psi Pounds Per Square Inch lpm Liters Per Minute SAFETY Information Warnings and Cautions DANGE...

Page 4: ...urns electrocution fire or injury to persons The Easy Comp Compressor should never be left unattended when running Close supervision is necessary when the Compressor is used by on or near children or...

Page 5: ...s Length 10 25 in 26 0 cm Width 5 25 in 12 3 cm Height 9 5 in 24 1 cm Weight 10 8 lbs 4 9 kg Shipping Weight 12 5 lbs 5 7 kg Electrical 120 VAC 60 Hz 5 Amps Operating Temperature Range 50 F to 104 F 1...

Page 6: ...N CAUTION Missing or illegible labels must be replaced contact Precision Medical Inc Pressure Gauge air outlet fitting regulator knob suction feet filter endcap power cord on off switch air filter ass...

Page 7: ...ceptacle marked Hospital Grade OPERATING INSTRUCTIONS WARNING Read this User Manual before installing or operating the Easy Comp Compressor CAUTION Inspect the Easy Comp Compressor for visual damage D...

Page 8: ...check air filter for dust buildup 3 If dust buildup occurs remove air filter and wash in warm soapy water and rinse 4 Absorb excess water from filter with a dry towel 5 Return filter and end cap Clean...

Page 9: ...dical Inc Return Policy available on the Internet www precisionmedical com Disposal Instructions Dispose of Bio waste products as prescribed by your Healthcare Professional or Healthcare Facility Prot...

Page 10: ...ower cord not connected properly 3 Compressor overheated 1 Push On Off switch to ON position 2 Check power cord 3 Shut Compressor off wait 15 minutes be sure vents are clear B Unable to adjust pressur...

Page 11: ...es about the merchandise described in this contract and any such statements shall not be relied upon and are not part of the contract for sale Thus this writing is a final complete and exclusive state...

Page 12: ...nc 300 Held Drive Northampton PA 18067 USA Toll Free Tel 800 272 7285 Toll Free Fax 800 353 1240 Tel 001 610 262 6090 Fax 001 610 262 6080 www precisionmedical com ISO 13485 Certified 1971 Rev7 E 05 2...

Reviews: