Figure 1

 -

Overall Dimensions

Figure 2

Under specific test conditions this heater has been
shown to deliver heat at rates ranging from 

9,527

to 

18,761 

Btu/hr.

THIS APPLIANCE NEEDS PERIODIC INSPECTION AND
REPAIR FOR PROPER OPERATION. CONSULT
OWNER’S MANUAL FOR FURTHER INFORMATION. IT
IS AGAINST FEDERAL REGULATIONS TO OPERATE
THIS APPLIANCE IN A MANNER INCONSISTENT WITH
OPERATING INSTRUCTIONS IN THE OWNER’S
MANUAL.

This wood heater has a manufacturer-set minimum low
burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this
wood heater in a manner inconsistent with operating
instructions in this manual. U.S. ENVIRONMENTAL
PROTECTION AGENCY Certified to comply with 2020
particulate emission standards using pellet fuel. It is
recommended that smoke and carbon monoxide detectors
be installed in the area where the heater is to be installed.

 

OUTSIDE COMBUSTION AIR IS MANDATORY IN
MOBILE OR MODULAR HOME INSTALLATIONS.

CAUTION: DO NOT CONNECT TO ANY AIR
DISTRIBUTION DUCT OR SYSTEM.

VENTING AND INSTALLATION
CLEARANCES

CONTACT LOCAL BUILDING OFFICIALS ABOUT RE-
STRICTIONS AND INSTALLATION INSPECTION
REQUIREMENTS IN YOUR AREA.

A LISTED, 4" MINIMUM TYPE "L" PELLET VENT PIPE
IS MANDATORY ON ALL INSTALLATIONS.

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT, DO NOT CONNECT
THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER
APPLIANCE.

Use only listed 3" minimum Type "L" pellet vent and
components for installation. The exhaust vent system must
be attached to the unit and to each adjoining section. All
joints for connector pipe shall be fastened with at least three
screws. If vented horizontally, joints shall be made gas-tight
by sealing with high temperature silicon or material specified
by vent pipe manufacturer. Failure to use listed pellet vent
pipe or install it per manufacturers instructions will void your
warranty.

INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER

Vent Pipes’ inner and outer diameters may vary. Check with
vent pipe manufacturer for further details. 

WARNING: Installation of a Mobile Home Attachment Kit
P/N 10412 and outside combustion air is mandatory in
mobile or modular home installations

 although it may

also be used in all residential applications.

An outside air inlet MUST be provided for combustion
and ventilation air.

  The air inlet must remain unrestricted

while unit is in use.  Outside air connection is located in the
rear of the heater (

Figure 2

). Use conduit pipe or metal flex

pipe and/or fittings to make the air intake hook-up.

CAUTION: STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALLS AND CEILING/ROOF MUST BE
MAINTAINED.

1.

When deciding on the location of your heater and vent
pipe, try to minimize the alteration and reframing of
structural components of the building. 

Vent pipe must

be installed so that access is provided for
inspection and cleaning

.

2.

Avoid installing heater in high traffic areas. Keep
children well away from the heater when in operation.

3. A 3" clearance to combustibles must be maintained

for horizontal and vertical venting. When passing
through ceilings or walls, you must use a listed wall
thimble, making sure all combustible materials and
insulation products are a minimum of 3" away from the
pellet vent pipe.

PELLET HEATERS REQUIRE A MINIMUM 5' VERTICAL
RISE FOR PROPER OPERATION. ADDITIONAL RISE
OF  2'  FOR  EVERY  1'  HORIZONTAL  BEYOND  1  ½'.
MINIMUM  DRAFT  REQUIRED  IS  -.01  IN.WC.  @
CONNECTION

.

LOW DRAFT CONDITIONS RESULT IN OVERFEEDING
AND POOR COMBUSTION. 

2

Summary of Contents for EF5001U-C

Page 1: ...n approved for use with a 3 Type L Pellet Vent System or recommended 4 over 10 vertical NEVER use gasoline gasoline type lantern fuels kerosene charcoal lighter fluid or similar liquids to start or fr...

Page 2: ...ented horizontally joints shall be made gas tight by sealing with high temperature silicon or material specified by vent pipe manufacturer Failure to use listed pellet vent pipe or install it per manu...

Page 3: ...ed behind the heater before going up into the chimney This is necessary in order to remove fly ash accumulation 6 Exit termination distance to openings a 3 ft minimum above any forced air inlet locate...

Page 4: ...ve factory jump wire and hook up thermostat wires to terminals Figure 7 8 c Locate thermostat approximately 10 to 12 feet from heater or in area that requires steady temperature d Run thermostat wires...

Page 5: ...activated and the stove operates based on the EasyFire digital control system requirements If the house AC power should quit the AutoLite system will not be available however with the optional battery...

Page 6: ...stove will begin to heat up When the stove reaches start up operating temperature it will then switch to the control panel setting and begin it s automatic operation cycle Feed Trim Adjustment Undern...

Page 7: ...ring to return against stop Figure 10 11 Once ash box is full box should be placed in a non combustible floor or on the ground well away from all combustible materials pending final disposal If the as...

Page 8: ...uires routine maintenance for maximum performance and is mandatory for the warranty to remain in effect The following procedures should be studied carefully and performed regularly as indicated 1 Fly...

Page 9: ...place with Pyro Ceramic Glass only Refer to parts list for specifications TROUBLE SHOOTING The following scenarios are provided in order to help you locate a difficulty if the heater performs in a man...

Page 10: ...Problem Feed system jammed Solution This condition is caused by fuel contaminated with hard materials such as rocks or metal objects To correct this remove all pellets from hopper Unplug heater from a...