RM-208 CB.13.01 Easy Line Documentation
RDN 10000795
13
20.03.2019
8 Text messages on the display
Display
Explanation
Reset status and text version
The text message is displayed for approx. 1 second after the voltage is
switched on.
Reset RM204VXX
Controller is not enabled through inputs 10 and 11.
Stand By
+ - Val.No
The control has been enabled via input 10, 11 and stopped via input 12,
13.
Cleaning Off
+ - Val.No
The control has been enabled via input 10, 11 and started via input 12,
13.
Cleaning On
+ - Val.No
Down time cleaning active
DTC Cleaning ON
+ - 000 Pcs
The alarm switching point for the service hours counter has been
exceeded.
Call Service
+ - Val.No
A connected I/O module RM-LV8 or RM-LV16 is out of order
or
the total number of valves (parameter P04) is set incorrectly.
or
the valve outputs of a connected I/O module RM-LV8 or RM-LV16 are not
taken in sequence.
RM-LVX Alarm
+ - Val.No