background image

DDK50 • DDK100E

Bubble Tubing Deicer Kit

Instructions for Operation • Safety • Warranty

Thank you for your purchase of an EasyPro bubble tubing deicer kit. EasyPro deicer kits 

are designed to be an energy efficient way to keep your dock, boat lift, piers, etc. free 

from ice formations. These kits are also great for shallow water aeration applications.
•  Bubble tubing lays on bottom and pushes warmer water from the bottom up to the 

surface preventing ice from forming.

•  Self weighted bubble tubing conforms to any shape needed.
•  Kits include compressor, 15' of 

5

/

8

" weighted feeder tubing, 50' or 100' bubble 

tubing, fittings and clamps.

•  Required cabinet or enclosure sold separately.

Safety and Electrical

Warning - Risk of electrical shock. For your protection always unplug the unit from 

its power source before installing or servicing.
Warning - This compressor is solely intended to pump air. It is not for use with oil, 

solvents or any petroleum products (gasoline, diesel, etc.).

•  Always use a properly grounded AC outlet. Keep plug end from moisture and do not 

attempt to plug in a wet plug.

•  Provide a “drip loop” for the line cord. This is a loop in the cord below the level of 

the receptacle or plug that prevents water from traveling along the cord into the 

receptacle.

•  Be sure that a Ground Fault Circuit Interrupter (GFCI) is installed in the branch circuit 

supplying the equipment.

•  Unit should be installed horizontally and above the height of water surface.
•  Do not submerse or flood compressor. Do not place compressor where it could fall 

into water.

•  Do not operate if power cord is damaged.
•  Use extreme caution when operation in winter. Danger due to thin ice can cause 

drowning. Unseen currents can cause thin ice in areas ling distances away from 

diffuser operation. Provide adequate warning for others when operating this system.

•  Always wear a Coast Guard approved life vest when working in or near water and 

follow all safety guidelines.

Note: EasyPro Pond Products is not responsible for losses, injury or death as a result of 

failure to follow these safety warnings, misuse or abuse of equipment.

DDK100E

DDK50

Summary of Contents for DDK50

Page 1: ...ne diesel etc Always use a properly grounded AC outlet Keep plug end from moisture and do not attempt to plug in a wet plug Provide a drip loop for the line cord This is a loop in the cord below the level of the receptacle or plug that prevents water from traveling along the cord into the receptacle Be sure that a Ground Fault Circuit Interrupter GFCI is installed in the branch circuit supplying t...

Page 2: ...o create curves and corners as needed Outlet Assembly Tee Assembly Coupling Tee Assembly Plug Plug Plug Compressor Compressor Compressor Bubble Tubing Deicer Kit Components Kit Compressor Part Compressor Feeder Tubing Bubble Tubing Repair Kits DDK50 SRC25 15 Weighted 50 SRC25K DDK100E SRC50 15 Weighted 100 SRC50K Coupling Tee Assembly Plug T Configuration Linear Configuration Closed Loop Configura...

Page 3: ...eder tubing 6 Secure weighted feeder tubing to the outlet assembly at the compressor with large clamp This connection can be submerged if necessary 7 Connect the bubble tubing to the feeder tubing with appropriate clamps Excess tubing can be trimmed to length at this point 8 When all connections are made and tubing is in place the system is ready for operation by plugging compressor into 120v GFCI...

Page 4: ...rges Be sure to include the RA number original receipt in the form of an invoice or sales receipt name return address and phone number inside of the package No warranty claims will be honored without the original receipt Ensure the product is properly packaged and insured for the replacement value Damage due to improper packaging is the responsibility of the sender The manufacturer or supplier sha...

Reviews: