PUMP END ASSEMBLY

1.  Clean and inspect all pump parts (0-ring, seal seats, motor shaft, etc.).
2.  Apply sealant to the bracket bore ID wall and around the seal case - follow sealant mfg. instructions. We recommend using Gasgacinch

®

. Silicone 

sealant can also be used. 

3.  Press carbon graphite seal into bracket while taking care not to damage carbon graphite face.
4.  Place slinger (rubber washer) over motor shaft and mount bracket to motor.
5.  Carefully, lubricate the seal seat elastomer OD and impeller hub ID with water. Press the seal seat into the impeller hub making certain that the ce-

ramic is in evenly - the sealing surface should be parallel with the impeller hub.

6.  Carefully lubricate carbon-graphite and ceramic sealing surfaces with CLEAN water. Do not use silicon lubricants or grease!
7.  Assemble bracket to motor with four M-bolts
8.  Thread impeller onto shaft and tighten! If required, remove motor end-cap and use a screwdriver on the back of motor shaft to prevent shaft rotation 

while tightening. Replace motor end cap.

9.  Seat large O-ring in volute slot and assemble volute to bracket with seven 1/4-20 x 2 

3

/

4

" hex cap screws, washers and nuts. Tighten in a cross pat-

tern (30 in-lbf). 

10. Install drain plug with its O-ring in volute drain hole.
11. Before operating pump, allow a proper cure time for the sealant used in step 2.        

DISASSEMBLY

1.  Shut off power to motor before disconnecting any electrical wiring from the back of the motor.
2.  Disassemble volute from bracket by removing the seven 1/4” - 20 threads per inch  x  2 3/4” hex cap screws.
3.   Remove cap covering shaft at back of motor and with a large screwdriver, prevent shaft rotation while unscrewing impeller.
4.  Remove ceramic piece from impeller. (If you are replacing the seal)
5.   Detach bracket from motor.
6.  Remove carbon-graphite seal from bracket by pressing out from the back. Do not dig out from the front! (If you are replacing the seal) 

VOLUTE

IMPELLER

WASHER &

LOCK NUT

BRACKET

M BOLT

LARGE

O-RING

SEAL

P-BOLT

& WASHER

DRAIN 

PLUG

& O-RING

DESCRIPTION

PART NUMBER

DRAIN PLUG

1000.110 LG

O-RING, DRAIN PLUG

E014B70

VOLUTE

K000.070 LG

LARGE O-RING

1000.061

IMPELLER

1000.054

SEAL 1000.0411
BRACKET

K000.030 LG

SLINGER

1000.010V

HARDWARE KIT

1000.502

SLINGER

MOTOR ILLUSTRATION IS FOR REFERENCE ONLY.

1

/

2

" FNPT

2.75

16.30

2.41

4.42

3.59

HIGH/LOW

TOGGLE SWITCH

Summary of Contents for EX6750-2

Page 1: ...ill out the warranty registration card in this manual S N XXXX XXXXXX EX6750 2 EasyPro TYPE STRAIGHT CENTRIFUGAL MOTOR NEMA C Face 56J HORSEPOWER 2 1750 RPM 1 5 3450 RPM VOLTAGE 115 ACCESORIES 90 CUBIC INCH STRAINER BASKETS 11 2 2 SWING CHECK VALVES 11 2 2 3 500 CUBIC INCH STRAINER BASKETS 11 2 2 3 MODEL SPEED INLET DISCHARGE MAX FLOW gph MAX HEAD feet MAX POWER watts MAX CURRENT amps volts MOTOR ...

Page 2: ...is not self priming It must not be run dry We recommend a flooded suction installation Please read carefully When properly installed the pump will provide dependable trouble free service ELECTRICAL HOOK UP 1 Check that supply voltages match the motor s requirements 2 Check motor wiring and connect according to instructions on motor to match supply voltage 3 Power cord should be protected by condui...

Page 3: ...end cap 9 Seat large O ring in volute slot and assemble volute to bracket with seven 1 4 20 x 2 3 4 hex cap screws washers and nuts Tighten in a cross pat tern 30 in lbf 10 Install drain plug with its O ring in volute drain hole 11 Before operating pump allow a proper cure time for the sealant used in step 2 DISASSEMBLY 1 Shut off power to motor before disconnecting any electrical wiring from the ...

Page 4: ...ndifanyprovisionshallbedeemedinvalid theremainingprovisionsshallremaininfullforceandeffect 11 Rights under this warranty are not assignable without the express prior consent in writing by EP and regardless of the terms of such consent in writing such assignee shall have no greater rights than his assignor had against EP Symptom Problem Resolution No Flow Insufficient Prime Prime system with water ...

Reviews: