background image

EX8800 • EX11200 • EX13200

Reliability You Can Count On!

© 2010 EasyPro, Inc

Pg. 2

ELECTRICAL HOOK-UP

1.  Check that supply voltages match the motor’s requirements.
2.  Check motor wiring and connect, according to instructions on motor, to match supply voltage. 
3.  Power cord should be protected by conduit or by cable and be of proper gauge. It should be no longer than necessary.
4.  Power should be drawn directly from a box with circuit breaker protection or with a fused disconnect switch.

We congratulate you on your choice of the EX8800/EX11200/EX13200 Centrifugal Pump! It has been carefully designed using the advan-
tages of today’s technology and carefully constructed to give you the dependability of yesterday. To insure proper performance, we urge 
you to carefully follow the instructions in this manual. If you have any questions, call your nearest distributor or EasyPro for assistance.

INSTALLATION

Please read carefully! When properly installed the EX8800/EX11200/EX13200 will provide dependable trouble-free service.
1.  Locate the pump as near the water source as possible. A fl ooded suction situation is preferred. The pump is not self-priming, therefore, 

if the fl uid level is below the pump, a swing check valve must be installed and the pump primed prior to start-up. (Figure 2)

2.  Mount motor base to a secure, immobile foundation.
3.  Use only plastic fi ttings on both the intake and discharge ports. Seal pipe connections with Tefl on™ paste. These fi ttings should be self-

supported and in neutral alignment with each port. (i.e. Fittings must not be forced into alignment which may cause premature line failure 
or damage to the pump volute.) For non-fl ooded installations, a strainer basket and check valve are recommended.

4.  Never restrict the intake. Keep both input and discharge lines as free of elbows and valves as possible. Always use pipe of adequate 

diameter. This will reduce friction losses and maximize output.

5.  The EX8800 is not self-priming! It must not be run dry! We recommend a fl ooded suction installation. Please read carefully! When properly 

installed, the EX8800 will provide dependable, trouble-free service.

6.  For additional plumbing tips, review EasyPro’s website: www.EasyProPondProducts.com for pond plumbing and pump installation 

hints.

PUMP

SWING 

CHECK VALVE

FLOODED SUCTION

WARNING: DO NOT RUN DRY!

WARNING: ALWAYS SHUT OFF ELECTRICAL POWER BEFORE INSTALLATION AND / OR SERVICING THIS PUMP! ALL ELECTRICAL WIRING 
SHOULD MEET STATE AND LOCAL ORDINANCES. IMPROPER WIRING MAY NOT ONLY BE A SAFETY HAZARD BUT MAY PERMANENTLY 
DAMAGE THE MOTOR AND/OR PUMP! 230V 50 HZ MOTORS AVAILABLE - CONTACT YOUR SUPPLIER FOR INFORMATION.

BALL 

VALVE

(FIGURE 2)

SUCTION LIFT

Jolie 

Products 

Inc

Summary of Contents for EX8800

Page 1: ...ternal out of pond pump It is NOT submersible Do NOT allow this pump to become submerged Never run dry Max case pressure 65 PSI Please fill in for future reference MODEL ________________________________________ SERIAL NUMBER _______________________________ DATE PURCHASED _____________________________ Please fill out the warranty registration card in this manual EasyPro EX8800 S N XXXX XXXXXX Model...

Page 2: ...imed prior to start up Figure 2 2 Mount motor base to a secure immobile foundation 3 Use only plastic fittings on both the intake and discharge ports Seal pipe connections with Teflon paste These fittings should be self supported and in neutral alignment with each port i e Fittings must not be forced into alignment which may cause premature line failure or damage to the pump volute For non flooded...

Page 3: ...lute to bracket with seven 1 4 20 x 2 3 4 hex cap screws washers and nuts Tighten in a cross pattern 30 in lbf 10 Install drain plug with its O ring in volute drain hole 11 Before operating pump allow a proper cure time for the sealant used in step 2 DISASSEMBLY 1 Shut off power to motor before disconnecting any electrical wiring from the back of the motor 2 Disassemble volute from bracket by remo...

Page 4: ...perty damage and to the extent not unconscionable for personal injury damage Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you 9 This warranty does not apply to any malfunction arising out of any application of this product other than normal use unless such application is upon request specifically a...