26
easyRAID Q16
Serial ATA Disk Array Systems
3
Ma
inten
ance
–
Rep
lacing a Powe
r Supp
ly
Replacing a Power Supply
The disk array system is equipped with a Power Supply Fail Indicator LED at the front of the unit
that turns red when one of the power supplies fails. The message “Power x failure” also appears
on the LCD panel, where x refers to power supply 1, or 2, and an audible alert sounds.
Power supplies are hot swappable, which means that they can be inserted and removed while the
disk array is powered on and operating. Follow these instructions to replace a failed power sup-
ply.
1
Identify the power supply that has failed.
2
Remove the power cable from the power supply connector at the rear of the unit.
3
Loosen the power supply retaining screw.
Note
Turn off the audible alert by pressing the Up and Down function but-
tons on the front panel twice simultaneously.
Note
The system is equipped with auto switching power supplies that
can run on 100 to 240 VAC.
Host Port 2
Term
MODEM
UPS
Host Port 1
Power Supply 1
Power Supply 2
oGGwGGY
Fan 1
Power 1
Chap3.fm Page 26 Thursday, September 29, 2005 10:52 AM
Summary of Contents for ERQ16-F2R3
Page 2: ......
Page 4: ......
Page 6: ......
Page 20: ......
Page 40: ...Chap3 fm Page 30 Thursday September 29 2005 10 52 AM ...