16
easyRAID Q16QS-4GR3
SAS Disk Array System
3
Ma
inten
ance
–
Rep
lacing a Powe
r Supp
ly
Replacing a Power Supply
The disk array system is equipped with a Power Supply Fail Indicator LED at the front of the unit
that turns red when one of the power supplies fails. The message “Power x failure” also appears
on the LCD panel, where x refers to power supply 1, or 2, and an audible alert sounds.
Power supplies are hot swappable, which means that they can be inserted and removed while the
disk array is powered on and operating. Follow these instructions to replace a failed power sup-
ply.
1
Identify the power supply that has failed.
2
Remove the power cable from the power supply connector at the rear of the unit.
3
Loosen the power supply retaining screw.
Note
Turn off the audible alert by pressing the Up and Down function but-
tons on the front panel twice simultaneously.
Note
The system is equipped with auto switching power supplies that
can run on 100 to 240 VAC.
Term
UPS
LAN
Ch 3
Ch 1
EXP
Ch 4
Ch 2
Power Supply 1
Power Supply 2
Term
UPS
Ch 3
Ch 4
Ch 1
Ch 2
LAN
EXP
Power Supply
retaining screw
Summary of Contents for Q16QS-4GR3
Page 2: ......
Page 3: ...easyRAID Q16QS 4GR3 iSCSI 1Gb to SAS Disk Array System Hardware User Manual ...
Page 4: ......
Page 6: ......
Page 12: ......
Page 25: ...easyRAID Q16QS 4GR3 SAS Disk Array System 15 2 Basic Configuration Mounting in a Rack ...
Page 26: ......
Page 32: ......