background image

•  Please read and understand all safety precautions and user instructions prior to use. Call Altimate Medical at 800-342-8968 or 

 

507-697-6393 with any questions or for additional information.

•   If a user does not meet the specifications below and has not been properly fitted by a qualified therapist or physician, 

 

Altimate Medical, Inc., does not recommend using the EasyStand Zing. 

  

 

Zing Size 1- is designed to accommodate most individuals up to 44” (112 cm) and up to 70 lbs. (32 kg).   

For more detailed specifications visit our website www.easystand.com

•   The EasyStand Zing should not be used without first consulting a qualified physician. Failure to consult a qualified physician prior 

 

to using the EasyStand Zing could lead to severe medical problems. We recommend a good standing program be established and 

 

supervised by a qualified, registered physical/occupational therapist.

•   The EasyStand Zing should always be used with a qualified adult attendant present. Consult with your therapist or physician for proper  

 

foot placement and angle. Never leave a child unattended in the Zing.

•   Do not make foot plate adjustments to the Zing while a child is standing. 
•   It is necessary to inspect your EasyStand Zing at least weekly to ensure it is in safe operating condition. Pay particular attention for loose 

 

hardware. Replacement of worn parts, major adjustments, or any other important corrections should be handled by an authorized dealer 

 

or service center. Only Altimate Medical, Inc. approved replacement parts should be used to ensure safety and performance.

•  If your EasyStand is being used in the home environment, please inspect your unit prior to each use to ensure there is no damage or 

 

unexpected wear to the EasyStand that may have been caused unintentionally by pets, pests or children.      

•   Ensure the necessary support and alignment options are in position prior to placing the user into the standing position.  
•   Storage/Transport Conditions: Temperature: 14˚F -122˚F (-10˚C - 50˚C), Relative humidity: 20% - 90% at 86˚F (30˚C), Atmospheric Pressure:  

 

700 to 1060hPa.

•  If the unit was exposed to temperatures of less than 50˚F (23.5˚C), allow unit to warm to room temperature before use. 
•  The expected service life of an EasyStand is considered 5 years under normal use conditions. Note: This may vary based on frequency of  

 use. 
•   Standing equipment is designed for indoor use on level surfaces only. Keep casters locked while in use.  
•   It is not recommended to transport the unit with a user in the standing position.  
•  Extreme movements laterally or front to back may cause the unit to tip.    
•   It is recommended the equipment be stored at normal room temperature and humidity levels. 
•   Altimate Medical products are specifically designed to be used with Altimate Medical accessories and options. Unless otherwise noted, 

 

accessories and options from other manufacturers have not been tested by Altimate Medical and are not recommended for use with 

 

Altimate Medical products.

•  Product Modifications made without express written consent (including, but not limited to, modification through the use of unauthorized 

 

parts or attachments) are not recommended and will void the product warranty.    

 Caution: This equipment is designed to accommodate a range of users; therefore the unit has various adjustment slots and holes. 

 

Avoid placing fingers or other body parts in any of these areas.  

 Caution: While in use this equipment has various moving parts, familiarize yourself with the unit and avoid placing hands or fingers 

 

near any of these areas.  

 Caution: Advise bystanders to keep clear of the unit while in use.

Safety Precautions 

!

!

!

Page 2

Page 17

Parts Detail-Supine

Summary of Contents for ESPA5520G

Page 1: ...Owner s Manual MPS Supine size1 ...

Page 2: ...io ambiente y recicle este producto al finalizar su vida útil en el lugar de reciclaje correspondiente Siate responsabili verso l ambiente e riciclate questo prodotto al termine della sua vita d uso presso la vostra sede di riciclaggio Kierrätä tämä tuote sen käyttöiän lopussa ympäristövastuullisella tavalla paikallisella kierrätyslaitoksella Var miljömedveten och återvinn denna produkt efter dess...

Page 3: ...Table of Contents Introduction 1 Safety Precautions 2 Assembly 3 Adjustments Usage 9 Parts Detail 17 Maintenance 19 Limited Warranty 20 Date Purchased Serial ...

Page 4: ...al supplier or call Altimate Medical Inc at 800 342 8968 or 507 697 6393 It is necessary to inspect your EasyStand Zing at least weekly to ensure it is in safe operating condition EasyStand adjustments that are listed in the product owner s manual can be made by the operator by following the instructions for use After an adjustment is made inspect the EasyStand to ensure all hardware and adjustabl...

Page 5: ... wear to the EasyStand that may have been caused unintentionally by pets pests or children Ensure the necessary support and alignment options are in position prior to placing the user into the standing position Storage Transport Conditions Temperature 14 F 122 F 10 C 50 C Relative humidity 20 90 at 86 F 30 C Atmospheric Pressure 700 to 1060hPa If the unit was exposed to temperatures of less than 5...

Page 6: ... Assembly B Mast C Foot Plates D Hip Supports E Calf Pads F Knee Pads G Lateral Supports H Tray 2 Remove 4 bolts and washers from the base wheel assembly 3 If the gas spring lockout was ordered make sure the gas spring lockout located on the mast is in the unlocked position as shown G H A D E F B C Page 3 1 2 3 ...

Page 7: ...hown Depress the foot pedal 4B Allow the mast post to come up to a vertical position 5 Flip the base wheel assembly over and place onto the mast as shown 6 Start all 4 bolts and washers you removed in step 2 Do not tighten at this time 5 6 4B 4A ...

Page 8: ...en started tighten all 4 bolts securely Place unit onto its wheels 8 If the calf pad with knee strap was ordered place the assembly onto the legs as shown 9 Once the calf pad with knee strap is in position tighten knobs securely 8 9 7 ...

Page 9: ...d position as shown Insert the calf pads into the clamps on the multi adjustable knee pads 11 Insert multi adjustable knee pads into the bracket on the outer side of the legs Tighten securely 12 If the platform foot plate was ordered place the assembly onto the legs as shown Tighten securely 11 12 10 Clamp ...

Page 10: ...o the legs Tighten knobs securely 14 If the hip supports were ordered insert hip supports into the bracket behind the pelvic pad Tighten securely 15 If the lateral supports were ordered insert lateral supports into the bracket behind the upper body support pad Tighten securely 14 15 13 ...

Page 11: ...d position and tighten knob securely 17A If the multi adjustable tray was ordered there are 2 knobs in the parts bag Screw each knob into the tray bracket on the unit 17B Place the tray bracket assembly into the base Tighten securely Page 8 18 Remove head support and place the stem into the clamp as shown Tighten securely 18 17A 17B 16B 16A ...

Page 12: ... the knob past its stop will damage the mechanism The tray may now be removed completely or adjusted to the desired position using the click detent positions as a guide Multi Adjustable Tray Depth 21 Loosen knob under the tray pull or push into desired position Tighten securely Multi Adjustable Tray Angle 22 To adjust tray angle loosen ratchet handles on both sides of the tray set to desired posit...

Page 13: ...unit Always tighten securely The depth can be adjusted by loosening the two bolts once the desired position is reached Tighten securely 27 The lateral supports have a number of attachment holes on the back of the pad which will allow for additional positions vertically and horizontally The pads may also be bolted at a high low or neutral position in order to effect greater pad range 28 To adjust t...

Page 14: ...Tighten securely 31 To adjust the multi adjustable knee pad depth loosen the knob Adjust to desired position Tighten securely 32 To adjust the multi adjustable knee pad position loosen knob and rotate to desired position Tighten securely Independent Adjustable Calf Pads 33 To adjust the independent adjustable calf pad depth loosen the knob Adjust to desired position Tighten securely 34 Remove bolt...

Page 15: ...h loosen the knob on the back of the headrest and slide into desired position Tighten securely To adjust the head support angle loosen the ratchet handle and place into desired position Tighten securely Upper Body Support Pad 37 To adjust the upper body support pad height loosen knob depress spring button and adjust to desired position Tighten securely 37 36 35 ...

Page 16: ...handles to tilt foot plates Tighten securely 42 Adduction Loosen knobs to slide foot plates together Tighten knobs securely 43 Forward Aft Loosen knobs underneath foot plates slide foot plates into position Tighten knobs securely 44 Toe in Toe out Loosen knobs underneath foot plates slide foot plates into position Tighten knobs securely 45 Abduction Loosen ratchet handles to spread apart foot plat...

Page 17: ...Page 14 Leg Abduction 46 Loosen knob behind the pelvic pad 47 Abduct each leg out to the desired position up to 30 degrees per leg Tighten securely 46 47 ...

Page 18: ...e done with the user in the unit Prone MPS only 50 Flip the lever located behind the pad to the prone position 51 Adjust to the desired prone position by depressing the foot pedal and tilting This can be done with the user in the unit Dual Control 52 Squeeze the hand lever to place the unit in the desired position 53 Use the foot pedal to place the unit in the desired position 51 49 48 53 52 50 ...

Page 19: ...the knob is vertical and locks into postion The gas spring is now locked from unintended movement Directional Locking Caster 56 Lock the right rear caster to allow the unit to guide straight Locking the directional caster locks the directional position of the caster This will not prevent the caster from rolling Gas Spring Lockout 56 55 54 ...

Page 20: ...Page 17 Parts Detail Supine ...

Page 21: ...Parts Detail MPS multi position stander Page 18 ...

Page 22: ... the covers Do not dry clean any upholstery items If the EasyStand is being used with one user clean the EasyStand on a monthly basis or as needed If the EasyStand is being used in a multiple user environment the EasyStand should be cleaned after each use Urethane Coated Fabrics and Hygienic Washable Covers Dartex or generic equivalent The recommended cleaning and disinfection instructions should ...

Page 23: ... apply to serial numbered products if the serial number has been removed or defaced Products subject to negligence abuse misuse improper operation improper maintenance improper storage or damages beyond Altimate Medical s control are not covered by this warranty and that evaluation will be solely determined by Altimate Medical Products modified without Altimate Medical s express written consent in...

Page 24: ...s a policy of continual product improvement and reserves the right to change features specifications and prices without prior notification Check with AMI for latest info FORM ZINGMPS1MAN 051215 REVA Copyright 2015 Altimate Medical Inc All rights reserved Printed in the U S A 262 West 1st St Morton MN 56270 USA Toll Free 800 342 8968 or 507 697 6393 Fax Free 877 342 8968 or 507 697 6900 email info ...

Reviews: