Document Reference No.: ES_000005
USB2-F-7x01 Full-Speed USB to 1-Port CANbus Adapter User Guide
Version 1.3
Clearance No.: ES#02
©2008 - 2010 EasySYNC Ltd.
24
4.1.9
Echo / Synchronize (E)
Summary
Clear transmit data buffers. Data buffers should be cleared immediately after opening the CAN
channel to prevent erroneous as a result of sending old data in the buffer.
Definition
E<CR>
Parameters
None
Remarks
Example:
E<CR>
Clear data buffers.
Return Codes
E<CR> = OK
<BELL> = ERROR