Remark
:
To avoid the float displaced in transportation
,
please adjust the water
level when the first time using.
)
6. Regular failure and failure elimination
Fault symptom
Reason
Remove method
Not working
a) No Power
b) Fuse blown
c) The power switch is not on
d) Humidity over the settled
a) Check the circuit, power
restoration
b) Replace the fuse
c) Turn on the power switch
No water adding
a) No water in the water supply
pipe
b) The water float is blocked
c) The water supply pressure is
not enough
a) Check the water supply
circuit
b) Remove the foreign matter in
the float
c) The pressure must reach
5KG.
Don’t stop when
adding water
a) The water float is displaced
b) There is foreign matter in the
float
c) The float is damaged
a) Adjust it to the correct
position
b) Remove the foreign matter
c) Replace the float
No fog outlet
a) The voltage 5% lower than
the standard
b) The water is too hard
c) Too dirty in the tank
a) Check the power or the
current plate
b) Clean the water tank
,
replace
the clean water
c) Clean the tank.
Water exceed
from the tank
a) Leaking from the water tank
b) The fog poured backward and
the blower outlet overflow
a) Mend the tank or replace a
new one
b) Check the blower outlet
Fog capacity
a) Too much lime scale in the a) Clean the water tank and the