Polar Compressor Rotary Screw Compressors
Revision July.2015
www.eatoncompressor .com
877.283.7614
15 |
P a g e
It’s recommended not set
the
unload delay too low. If
the compressor starts more than 5 times per
hour, it could cause unnecessary wear to
components.
Enter in the 6 Digit Password 6 6 6 6 6 6,
by using the Up Arrow to set the digit to 6
then press Enter to move to the next digit,
and press the Up Arrow to set to 6, repeat
until last digit is set to 6, then press Enter.
Press both Up & Down
Arrows again if the wrong password is
entered.
3.
Arrow down to 5)WORKING
TIMER and press Enter.
4.
Arrow down to Wt4 (Unload delay time).
Press Enter and the time flashes and can
be changed by using the Up & Down
Arrows. Press Enter again to confirm the
setting.
(See chart on page 13 of PLC manual.)
5.
Once satisfied with all settings, press
Down Arrow until you are back to the
Main Screen.
Following replacement times are important
for safe operation. Remember to clear
lifetime and reset maintenance timer after
replacements are made. Refer to PLC
manual for more details.
Maintenance Notifications
Component
(PLC)
Name)
Lifetime (hrs)
Air Filter
CAF
2000
Oil Filter
COF
2000
Air/Oil Separator Filter
CSF
2000
Lubricating Oil
C--=
2000
Check Compressor
C--h
2000
Motor Bearing Grease
BL
10,000