7.5 Communication Port

The type of  signals, serial command(RS232), is provided by the UPS to communicate with a host
computer. The RS232 communication port transmits both utility power and UPS status to the host
computer, providing the host computer with proprietary command sequence to monitor the utility
power and UPS status and to control the UPS output.

The data format of RS232 is listed as followed:
       Baud Rate       :  2400 bps
       Data Length    :   8 bits
       Ending Bit       :   1 bit
       Parity Bit         :   none

7.5.1 RS232 interface

The following is the pin assignment and description of DB-9 connector.

Pin# 

Description 

I/O 

RS232 Rx 

Input 

RS232 Tx 

Output 

Ground 

Input 

 

Figure 2: RS232 Interface

7.4 EMC

W.u.

7. TECHNICAL DATA

-EFT 

IEC61000-4-4 

Level 4 

-Surge 

IEC61000-4-5 

Level 4 

-ESD 

IEC61000-4-2 

Level 4 

-RS 

IEC61000-4-3 

Level 3 

-Conduction 

FCC PART 15 

Class B 

DX1000/3000

 

-Radiation 

FCC PART 15 

Class B 

 

Summary of Contents for 1000L

Page 1: ......

Page 2: ...5 TROUBLESHOOTING 8 6 M AINTENANCE 9 6 1 Operation 9 6 2 Storage 9 7 TECHNIC AL DATA 10 7 1 Electrical specifications 10 7 2 Typical stored energy time Battery mode 10 7 3 Dimensions and w eights 10...

Page 3: ...s A rectifier converts the alter nating current from the socket outlet to direct current This direct current charges the batteries and powers the inverter On the basis of this DC voltage the inverter...

Page 4: ...ed by Personnel Knowledgeable of Batteries and the Required Precautions Keep Unauthorized Personnel Away from Batteries CAUTION To reduce the risk of fire unit input connect only to a circuit provided...

Page 5: ...tem are still connected to the bat tery and are still electrically live and dangerous Before carrying out any kind of servicing and or maintenance disconnect the batteries and verify that no current i...

Page 6: ...oustic alarm can be deactivated Standby Switch The UPS system switches to Standby mode when the Standby button is pressed Then the inverter is off Figure 1 Display panel Indicator 1 Fault Indicator 2...

Page 7: ...ltage provided by the mains power supply system via the bypass INVERTER LED The green coloured INVERTER LED lights up when the UPS system is supplying voltage provided by the mains power via the inver...

Page 8: ...ck available for input as well The wiring configuration is shown in the following diagram 4 Connect your computer to the outlet sockets of the UPS system as shown in the above diagram 5 Fully charge t...

Page 9: ...not connect the UPS to any load yet Then connect the power cord of the UPS to supply utility power to the UPS to make the UPS operate in utility power mode 8 4 Connect the plug of the external battery...

Page 10: ...nd BATTERY LED lights up Input power and or frequency are out of tolerance Check input power source and inform dealer if necessary LINE and BYPASS LED light up even though the power supply is availabl...

Page 11: ...the batteries must be exchanged In this case please contact your dealer 6 2 Storage If the batteries are to be stored in temperate climatic zones they should be charged every three months for 1 2 hour...

Page 12: ...wer rating 1kVA 0 7k W 1 5kVA 1 05kW 3kVA 2 1kW Voltage 110 115 120VAC Frequency 50Hz 60Hz 0 2Hz Battery Mode Wave form Sinusoidal BATTERIES STANDARD Number and type 3x12V7 2Ah 4x12V7 2Ah 8x12V7 2Ah M...

Page 13: ...o control the UPS output The data format of RS232 is listed as followed Baud Rate 2400 bps Data Length 8 bits Ending Bit 1 bit Parity Bit none 7 5 1 RS232 interface The following is the pin assignment...

Page 14: ...s mentioned above this series UPS has AS400 card an optional accessory for AS400 communication protocol Please contact your local distribu tor for details The following is the pin assignment and descr...

Page 15: ...re 5 Back view of DX1000LXL 8 APPENDIX Communication Port Breaker Input Socket Intelligent Slot Cooling Fan Output Socket RJ45 Communication Port Breaker Input Socket Intelligent Slot Cooling Fan Outp...

Page 16: ...ling Fan RJ45 Intelligent Slot Intelligent Slot Output Socket Output Socket Breaker Communication Port Input Socket Cooling Fan RJ45 Intelligent Slot Intelligent Slot Output Socket Output Socket Break...

Page 17: ...n RJ45 Intelligent Slot Communication Port Figure 8 Back view of DX3000L 8 APPENDIX Breaker Cooling Fan Communication Port Input Terminal Block Intelligent Slot Output Socket Fuse RJ45 External Batter...

Page 18: ...16 614 03752 00...

Reviews: