 Do not connect appliances or items of equipment which would overload the UPS system (e.g. laser

printers) to the UPS outlet socket.

 

 Place cables in such a way that no one can step on or trip over them.

Operation

 

 Do not disconnect the mains cable on the UPS system or the building wiring socket outlet (shockproof

socket outlet) during operations since this would cancel the protective earthing of the UPS system
and of all connected loads.

 

 The UPS system features its own, internal current source (batteries). The UPS output sockets may

be electrically live even if the UPS system is not connected to the building wiring socket outlet.

 

 In order to fully disconnect the UPS system, first press the Standby switch then disconnect the

mains lead or, on the permanently connected unit , isolate the incoming feeder.

 

 Ensure that no fluids or other foreign objects can enter the UPS system.

Maintenance, servicing and faults

 

 The UPS system operates with hazardous voltages. Repairs may be carried out only by qualified

maintenance personnel.

 

 

CAUTION

 - risk of electric shock. Even after the unit is disconnected from the mains power supply

(building wiring socket outlet), components inside the UPS system are still connected to the bat-
tery and are still electrically live and dangerous. Before carrying out any kind of servicing and/or
maintenance, disconnect the batteries and verify that no current is present.

 

 Only persons adequately familiar with batteries and with the required precautionary measures

may exchange batteries and supervise operations. Unauthorised persons must be kept well away
from the batteries.

 

 

CAUTION

 - risk of electric shock. The battery circuit is not isolated from the input voltage. Hazard-

ous voltages may occur between the battery terminals and the ground. Before touching, please
verify that no voltage is present!

 

 Batteries may cause electric shock and have a high short-circuit current. Please take the precau-

tionary measures specified below and any other measures necessary when working with batteries:

- remove wristwatches, rings and other metal objects.
- use only tools with insulated grips and handles.

 

 W hen changing batteries, install the same number and same type of batteries.

 

 Do not attempt to dispose of batteries by burning them. This could cause battery explosion.

 

 Do not open or destroy batteries. Escaping electrolyte can cause injury to the skin and eyes. It

may be toxic.

 

 Please replace the fuse only by a fuse of the same type and of the same amperage in order to

avoid fire hazards.

 

 Do not dismantle the UPS system.

2. IMPORTANT SAFETY INSTRUCTIONS

Summary of Contents for 1000L

Page 1: ......

Page 2: ...5 TROUBLESHOOTING 8 6 M AINTENANCE 9 6 1 Operation 9 6 2 Storage 9 7 TECHNIC AL DATA 10 7 1 Electrical specifications 10 7 2 Typical stored energy time Battery mode 10 7 3 Dimensions and w eights 10...

Page 3: ...s A rectifier converts the alter nating current from the socket outlet to direct current This direct current charges the batteries and powers the inverter On the basis of this DC voltage the inverter...

Page 4: ...ed by Personnel Knowledgeable of Batteries and the Required Precautions Keep Unauthorized Personnel Away from Batteries CAUTION To reduce the risk of fire unit input connect only to a circuit provided...

Page 5: ...tem are still connected to the bat tery and are still electrically live and dangerous Before carrying out any kind of servicing and or maintenance disconnect the batteries and verify that no current i...

Page 6: ...oustic alarm can be deactivated Standby Switch The UPS system switches to Standby mode when the Standby button is pressed Then the inverter is off Figure 1 Display panel Indicator 1 Fault Indicator 2...

Page 7: ...ltage provided by the mains power supply system via the bypass INVERTER LED The green coloured INVERTER LED lights up when the UPS system is supplying voltage provided by the mains power via the inver...

Page 8: ...ck available for input as well The wiring configuration is shown in the following diagram 4 Connect your computer to the outlet sockets of the UPS system as shown in the above diagram 5 Fully charge t...

Page 9: ...not connect the UPS to any load yet Then connect the power cord of the UPS to supply utility power to the UPS to make the UPS operate in utility power mode 8 4 Connect the plug of the external battery...

Page 10: ...nd BATTERY LED lights up Input power and or frequency are out of tolerance Check input power source and inform dealer if necessary LINE and BYPASS LED light up even though the power supply is availabl...

Page 11: ...the batteries must be exchanged In this case please contact your dealer 6 2 Storage If the batteries are to be stored in temperate climatic zones they should be charged every three months for 1 2 hour...

Page 12: ...wer rating 1kVA 0 7k W 1 5kVA 1 05kW 3kVA 2 1kW Voltage 110 115 120VAC Frequency 50Hz 60Hz 0 2Hz Battery Mode Wave form Sinusoidal BATTERIES STANDARD Number and type 3x12V7 2Ah 4x12V7 2Ah 8x12V7 2Ah M...

Page 13: ...o control the UPS output The data format of RS232 is listed as followed Baud Rate 2400 bps Data Length 8 bits Ending Bit 1 bit Parity Bit none 7 5 1 RS232 interface The following is the pin assignment...

Page 14: ...s mentioned above this series UPS has AS400 card an optional accessory for AS400 communication protocol Please contact your local distribu tor for details The following is the pin assignment and descr...

Page 15: ...re 5 Back view of DX1000LXL 8 APPENDIX Communication Port Breaker Input Socket Intelligent Slot Cooling Fan Output Socket RJ45 Communication Port Breaker Input Socket Intelligent Slot Cooling Fan Outp...

Page 16: ...ling Fan RJ45 Intelligent Slot Intelligent Slot Output Socket Output Socket Breaker Communication Port Input Socket Cooling Fan RJ45 Intelligent Slot Intelligent Slot Output Socket Output Socket Break...

Page 17: ...n RJ45 Intelligent Slot Communication Port Figure 8 Back view of DX3000L 8 APPENDIX Breaker Cooling Fan Communication Port Input Terminal Block Intelligent Slot Output Socket Fuse RJ45 External Batter...

Page 18: ...16 614 03752 00...

Reviews: