15 | 

Page 

01/03/2021 

AUG_Eaton-3SMini_V0

 

 

 

Problem 

Possible cause 

Action 

All LED are OFF 

The UPS is turned OFF 

Press 3s the ON/OFF button. 

UPS does not start 

 

This could be linked to 
initial state (out-of-box)   

 

Make sure that the UPS is plugged  in a 
wall outlet that delivers power and 
press three seconds the ON/OFF 
button. 
If this does not work, contact your 
local customer service. 

One LED remains 
OFF when UPS is 
fully charged, and 
battery level 
displayed 

LED is defective 

Contact your local customer service. 

UPS does not 
charge 

Power is not delivered  to 
UPS or batteries may be 
defective 
 

1) Ensure that charging is not 
interrupted. 
2) Check mains are delivering  power. 
3) Check that the input  cord is well 
plugged  in the UPS. 
4) Contact your local customer service. 

Load is not 
powered 

UPS is in Auto-Recovery 
(AR) mode 

Unplug  the equipment.   
1) Verify load electrical characteristics 
(voltage, power). 
2) Let the UPS cool down (keep device 
away from any heat source). 
Wait several minutes and try again. 

UPS is frozen and 
ON/OFF button is 
ineffective 

UPS is locked  

Disconnect equipment,  turn OFF UPS 
and unplug  it from mains. 
Wait a minute  and reconnect UPS. 
Turn it back ON. 
Other option:  Reset to factory settings: 
press 15 seconds from the OFF state 
(unplugged).  Then plug  UPS and 
restart UPS. 

 

 

Summary of Contents for 3SM36

Page 1: ...1 Page 01 03 2021 AUG_Eaton 3SMini_V0 X Eaton 3SMini 3SM36 3SM36B Advanced User Guide Copyright 2021 EATON All rights reserved AUG_EATON 3SMINI_V0 3SMini EMEA...

Page 2: ...2 Page 01 03 2021 AUG_Eaton 3SMini_V0 Special symbols The following are examples of symbols used on the UPS or accessories to alert you to important information...

Page 3: ...nstallation 6 4 1 Package contents 6 4 2 Safety 7 4 3 Power supply cord socket 8 4 4 Start UPS 9 4 5 Voltage setup 10 4 6 Connect the equipment 12 5 Other functions 13 5 1 Turn OFF turn ON 13 5 2 Disp...

Page 4: ...d the information and safety instructions provided Follow the instructions in the quick start guide and if necessary refer to this advance user guide To discover the entire range of Eaton products we...

Page 5: ...ni UPS plastic casing Removable AC input cord CEE7 7 FR DIN shown here Attached DC output cord 4x green LED Voltage Chapter 4 5 battery level Chapter 5 2 and abnormal situations Chapter 6 ON OFF butto...

Page 6: ...the Eaton 36W AC to DC UPS Barrel adaptor polarity Supplied input cord x1 Supplied barrel connectors x4 Supplied Quick start Safety notes x1 BS1363 3SM36B models or CEE7 7 FR DIN 3SM36 models Note Ext...

Page 7: ...hall be installed near the equipment and shall be easily accessible Ensure that AC main outlet is properly earthed The UPS and their batteries must be kept in a ventilated place Never expose the UPS t...

Page 8: ...nnect the UPS to the AC power source through a wall protected outlet equipped with an earth connector using the attached cord for a UPS with FR DIN CEE7 7 or British BS1363 sockets Figure 1 FR DIN exa...

Page 9: ...e has been appropriately setup see 4 5 Press the ON OFF button for three seconds The battery level is first displayed for five seconds then the LED indicates the output voltage level default 12V Figur...

Page 10: ...tage setup mode and select the appropriate output DC voltage corresponding to equipment nominal input voltage 9V 12 15V or 19V Press the ON OFF button 5 for eight seconds Important The LED and UPS wil...

Page 11: ...y pressing the ON OFF button quick press Note that the voltage is not active until the selection is confirmed Figure 5 Cycle through the voltage levels Once the voltage is selected then simply press e...

Page 12: ...12 Page 01 03 2021 AUG_Eaton 3SMini_V0 4 6 Connect the equipment Select the correct barrel adaptor and clip it on the UPS output connector Plug your equipment Your equipment is now backed up...

Page 13: ...F button 5 ON OFF or OFF ON Figure 6 Turn ON or OFF the UPS 5 2 Display battery level The battery level is automatically displayed when the UPS is on battery no mains On mains you can simply press the...

Page 14: ...ly returns to normal state once situation is back to normal Abnormal situation OTP Over Temperature Protection NTC temperature If situation remains the UPS enters AR mode to protect the equipment UPS...

Page 15: ...not delivered to UPS or batteries may be defective 1 Ensure that charging is not interrupted 2 Check mains are delivering power 3 Check that the input cord is well plugged in the UPS 4 Contact your lo...

Page 16: ...Output connection Barrel adaptors 5 5 x 2 5 5 5 x 2 1 4 75 x 1 7 3 5 x 1 35 Power rating 36W Battery type Li Ion x2 ICR18650 Cell weight 45g Max Battery capacity 3 7 V 2200mAh x2 UPS dimensions W x H...

Page 17: ...PS requires any type of transportation verify that the UPS is turned off More information on Eaton recycling 9 Service and support If you have any question or problem with the UPS call Eaton or your l...

Reviews: