background image

 

5E1200UI-KR 

5E1600UI-KR/5E2200UI-KR 

3.2

 

Front  panel 

 

 

 

 

 

 

 

 

 

 

3.3

 

Rear panel 

1.

 

USB communication port 

2.

 

ON/OFF Button 

3.

 

UPS status LED 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC Input 

Fan 

AC Output 

 

 

 

 

 

 

 

 

 

 

 

 

KR 

2  3 

Summary of Contents for 5E700UD-KR

Page 1: ...Eaton 5E Advanced User Guide 5E700UD KR 5E1200UI KR 5E1600UI KR 5E2200UI KR Copyright 2023 EATON All rights reserved DSD 5E2209 English...

Page 2: ......

Page 3: ...ort 9 5 Operation 10 5 1 Start up and normal operation 10 5 2 Starting the UPS on battery 11 5 3 UPS shutdown 11 5 4 Operating modes 12 5 5 Return of AC input power 12 6 UPS maintenance 13 6 1 Equipme...

Page 4: ......

Page 5: ...sk of energy or electrical shock or burn from high short circuit current Observe proper precaution Batteries may contain HIGH VOLTAGE and CORROSIVE TOXIC and EXPLOSIVE substances Information advice he...

Page 6: ...protection Eaton has implemented an environmental protection policy Products are devel oped according to an eco design approach 2 1 1 Substances This product does not contain CFC and HCFC This produc...

Page 7: ...ons concerning batteries The battery may be removed to comply with regulations and in view of correct disposal 2 2 Benefits The Eaton 5E uninterruptible power system UPS protects your sensitive electr...

Page 8: ...escription UPS Weights kg lbs Dimentions mm inch D x W x H 5E700UD KR 4 3 9 5 288 x 100 x 148 11 5 x 3 9 x 5 8 5E1200UI KR 8 2 18 2 330 x 133 x 180 13 0 x 5 2 x 7 1 5E1600UI KR 8 9 19 6 330 x 133 x 18...

Page 9: ...5 1 1 3 2 2 5E1200UI KR 5E1600UI KR 5E2200UI KR 3 2 Front panel 3 3 Rear panel 1 USB communication port 2 ON OFF Button 3 UPS status LED 1 AC Input 3 Fan 2 AC Output KR 2 3...

Page 10: ...aled damage 1 File with the carrier within 15 days of receipt of the equipment 2 Send a copy of the damage claim within 15 days to your service representative Check the battery recharge date on the sh...

Page 11: ...located on the back of the UPS correspond to the AC power source and the true electrical consumption of the total load Connect the UPS to the AC power source with cable through a wall outlet equipped...

Page 12: ...s Backup Protected outlets Plug critical equipment computer monitor modem etc to the backup pro tected outlets providing battery backup power taking care not to exceed the rated current indicated in a...

Page 13: ...soon as the AC cord is plugged in These are not affected by ON OFF button 4 4 USB COM port Connect the UPS to the computer using the USB cable Enhance your purchase by downloading the monitoring softw...

Page 14: ...buzzer temporarily when there is a fault occur or battery test fail 2 UPS on off Push the button for 2s then to power on off the UPS 3 Silence mode Let UPS working in the standby mode then to push the...

Page 15: ...tandby mode to Battery mode The indicator blinking and the buzzer snooze The UPS supplies power to your equipment 2 Check the UPS front panel display for active alarms or notices besides the Bat tery...

Page 16: ...low while in Battery mode the audible alarm beeps faster This warning is approximate and the actual time to shutdown may vary signifi cantly gracefully shutdown all applications on connected equipmen...

Page 17: ...temperature below 10 C 6 2 Storing the equipment If you store the equipment for a long period recharge the battery every 6 months by connecting the UPS to utility power The internal batteries charge...

Page 18: ...eries and must be disposed of properly For more information con tact your local recycling reuse or hazardous waste center Do not discard waste electrical or electronic equipment WEEE in the trash For...

Page 19: ...tlets are not supplied with power or the UPS cannot be turn on after pressing the button The ON OFF Button is not pressed or the ON OFF but ton is pressed too briefly Press the button continuously for...

Page 20: ...service representative 7 1 Service and support If you have any question or problem with the UPS call Eaton or your local ser vice representative in your country region Please have the following infor...

Page 21: ...lation Boost1 Vin 1 2 Boost2 Vin 1 4 Buck Vin 0 857 10 15 Efficiency 95 60 Frequency regulation Same as input 1 Hz Nominal output 220 230 240V Frequency Follows input frequency 50 60Hz Output overload...

Page 22: ...3 Performance EMC Emissions CISPR32 Class A IEC EN 61000 3 2 Flickers IEC EN 61000 3 3 Harmonics This is a category C2 Class A UPS product In a residential environ ment this product may cause radio in...

Page 23: ...131 F without battery Relative humidity Storage 0 93 non condensing Operation 0 85 non condensing Operating altitude 2000 m Transit altitude Up to 10 000 meters 32 808 ft above sea level Audible noise...

Page 24: ...connected to the UPS output Normal mode The normal UPS operating mode in which the AC source supplies the UPS which in turn provides AC power to the connected loads Normal AC source Normal source of...

Page 25: ......

Reviews: