Eaton 9PX Lithium-Ion User Guide P-164001006—Rev 03
7
Table 4. LCD Operating Status (Continued)
Operation status
Cause
Description
Battery mode
A utility failure has occured and the UPS
is on Battery mode.
The UPS is powering the equipment with
the battery power. Prepare your
equipment for shutdown.
End of backup time
The UPS is on Battery mode and the
battery is running low.
Low Battery Warning settings:
[Capacity] [0%] ... [100%]
[Runtime] [0mn] ... [60mn]
The alarm triggers when the set
percentage of battery capacity or
remaining back-up time is reached.
High Efficiency mode
The UPS is operating on High Efficiency
mode.
The UPS is powering and protecting the
equipment
Bypass mode
An overload or a fault has occurred, or a
command has been received, and the
UPS is in Bypass mode.
Equipment is powered but not protected
by the UPS.
22..66
D
Diissppllaayy FFuunnccttiioonnss
Press the (
) button to activate the menu options. use the two middle buttons (
and
) to scroll through
the menu structure. Press the (
) button to select an option. Press the ESC button to cancel or return to the
previous menu.
Table 5. Display Functions
Main menu
Submenu
Display information or Menu function
Measurements
[Load] W VA A pf / [Input/Output] V Hz /
[Efficiency] % / [Battery] % min V n°
EBM / [Battery remaining life] months /
[Average power usage] Wh / [Cumulated
power] Wh / BMS Information
Control
Go to Bypass
Transfers the UPS on Bypass mode
Load segments On/Off
Commands the load segments
Start battery test
Starts a manual battery test
Connectivity test
Tests dry contact relay outputs and relay
card contacts. Simulates line failure and
battery low
Function reset
Clears active fault, power usage, battery
remaining life, reset NMC, Restore
factory settings.
Settings
Local settings
Sets product general parameters
Summary of Contents for 9PX1000IRT2U-L
Page 32: ...26 Eaton 9PX Lithium Ion User Guide P 164001006 Rev 03 UPS Remote Control Functions...
Page 42: ...36 Eaton 9PX Lithium Ion User Guide P 164001006 Rev 03 Recycling The Used Equipment...
Page 46: ...40 Eaton 9PX Lithium Ion User Guide P 164001006 Rev 03 CE Compliance Contact...
Page 51: ...Eaton 9PX Lithium Ion User Guide P 164001006 Rev 03 45 Model Specifications...
Page 52: ...P 16400100603 P 164001006 03...