11
3. Technical Data
MANUAL CEAG AUtoMAtiC tEst systEM At-s
+
40071860177 (C) December 2016 www.ceag.de
3.8 Data Sheet for AT-S
+
SOU2
Type of system
AT-S
+
SOU2
Construction
Surface-mounted plastic distribu-
tor housing of thermoplastic with
transparent viewing door
Height
583 mm
Width
295 mm
Depth
129 mm
Weight
approx. 7.8 kg
Insulation class*
II
Degree of protection
IP 65
Colour
Grey (RAL 7032)
Cable entry
from above (with integral elastic
sealing membranes for cable
infeed, with cable infeed shield)
Hinge
left
Mains rated voltage
230V AC, 50 or 60 Hz
Ambient temperature operation
-5° C up to +35° C
Mains feed in (max. 10 mm² solid)
X1.1
Max. 4 circuits (max.4 mm²)**
X1.4
Connection to RS485 Bus (max. 4 mm²)
X1.1.RS485.A-B
Connection to 24V analog output (max. 4 mm²)
X1.1.+24V Out--24V Out
3.9 Data Sheet for AT-S
+
SOU1
Type of system
AT-S
+
SOU1
Construction
Surface-mounted plastic distribu-
tor housing of thermoplastic with
transparent viewing door
Height
458 mm
Width
295 mm
Depth
129 mm
Weight
approx. 7.4 kg
Insulation class*
II
Degree of protection
IP 65
Colour
Grey (RAL 7032)
Cable entry
from above (with integral elastic
sealing membranes for cable
infeed, with cable infeed shield)
Hinge
left
Mains rated voltage
230V AC, 50 or 60 Hz
Ambient temperature operation
-5° C up to +35° C
Mains feed in (max. 10 mm² solid)
X1.1
Max. 4 circuits (max.4 mm²)**
X1.4
Connection to RS485 Bus (max. 4 mm²)
X1.1.RS485.A-B
Connection to 24V analog output (max. 4 mm²)
X1.1.+24V Out--24V Out
* Connect the earth conductor inside the distributor housing.
** Max. 2.5mm² flexible with wiring sleeve. The final circuits get wired customised.