background image

4

EATON Char-Lynn  

VIS 45 Series Bearingless Motors Parts and Repair Manual  C-MOLO-TM006-E   March 2008

VIS Bearingless
Motors - 
45 Series

Disassembly

Screw, 12pt

End Cap

Seal, Square Cut

O-ring

Valve Plate

Seal, Square Cut

Geroler

Check Balls

Drive

Seal, Square Cut

Balance Plate 

Outer

Balance Plate 

Inner

Seal, Square Cut

Spring, Belleville 

Disc

Backup ring

O-ring

Flange

Face Seal

O-ring

Disassembly

1.

Cleanliness is extremely important when repairing

hydraulic motors. Work in a clean area. Before disconnect-
ing the hydraulic motor thoroughly clean the exterior.
Remove motor from application and drain the oil from 
the motor before disassembly.

2.

Remove the 9 cap screws and disassemble the motor 

in the vertical position as shown in Figure 1. 

Note placement of small ball checks in Geroler.

3.

Remove shuttle valve (and relief valve if applicable) 

from end cap.

4.

Remove two plugs from end cap (end ported motors only).

5.

Check all mating surfaces. To reduce the chance of leak-

age, replace any parts that have scratches or burrs. Wash
all metal parts in clean solvent. Blow them dry with 
pressurized air. Do not wipe parts dry with paper towels
or cloth as lint in a hydraulic system will cause damage.

Tools Required

– 1/4 inch Hex Key

– 3/16 inch Hex Key

– 5/8 inch Hex Key (End Ported Motor Only)

– Torque wrench - 200 Nm [150 lb-ft] capacity

Figure 1

Reviews: