9.0 TROUBLESHOOTING

If the unit does not operate properly check the following:
1) Check to see if all wires are securely connected to the

Addressable Relay II.

2) Check the baud rate selection.

3) Check the INCOM network wiring.

4) Check to see that the address is set correctly.

5) Check to see that the software is configured correctly.

There are no user serviceable parts on the Addressable

Relay II.  The user should not attempt servicing this

equipment.  Please contact your local Cutler-Hammer

representative or the Power Quality Technical Support

Center (PQTSC) for service information.

10.0 TECHNICAL ASSISTANCE

For additional information, technical assistance or referral

to a local authorize distributor, contact Power Quality

Technical Support Center (PQTSC) at 1-800-809-2772,

option 1 / option 1 (outside the United States please call

1-414-449-7100 option 1 / option 1).  You can also e-mail

us at pmpapps@eaton.com or visit us on the web,

www.cutler-hammer.eaton.com, and follow the power

management product link.
You can also access our searchable database C-H eXpert

that provides self-help solutions with troubleshooting

information. Simply connect to the C-H eXpert Web site at

http://chexpert.ch.cutler-hammer.com/chexpert 

and type

in a keyword or product for your particular technical

problem in the search box.

11.0 WARRANTY AND LIABILITY

INFORMATION

This instruction booklet is published solely for information

purposes and should not be considered all-inclusive.  If

further information is required, you should consult Cutler-

Hammer.  Sale of the product shown in this literature is

subject to terms and conditions outlined in appropriate

Cutler-Hammer selling policies or other contractual

agreements between the parties.  This literature is not

intended to and does not enlarge or add to any such

contract.  The sole source governing the rights and

remedies of any purchaser of this equipment is the

contract between the purchaser and Cutler-Hammer.
NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING

WARRANTIES OF FITNESS FOR A PARTICULAR PUR-

POSE OR MERCHANTABILITY, OR WARRANTIES ARIS-

ING FROM COURSE OF DEALING OR USAGE OF TRADE,

ARE MADE REGARDING THE INFORMATION, RECOM-

MENDATIONS AND DESCRIPTIONS CONTAINED HEREIN.
In no event will Eaton be responsible to the purchaser or

user in contract, in tort (including negligence), strict

liability or otherwise for any special, indirect, incidental or

consequential damage or loss whatsoever, including but

not limited to damage or loss of equipment use, plant or

power system, cost of capital, loss of power, additional

expenses in the use of existing power facilities or claims

against the purchaser or user by its customers resulting

from the use of the information, recommendations and

description contained herein.

FIGURE 8 - MOUNTING DIMENSIONS (IN INCHES)

Summary of Contents for Cuttler-Hammer Addressable Relay II

Page 1: ...v C For more information visit www cutler hammer eaton com Effective 1 05 INSTRUCTION LEAFLET IL17435 Rev C INSTRUCTIONS FOR THE ADDRESSABLE RELAY II USED IN THE INCOM NETWORKS OF CUTLER HAMMER POWERN...

Page 2: ......

Page 3: ...d to comply with local state and national regulations as well as safety practices for this class of equipment SECTION 3 0 CONTROL STATION The control station for the PowerNet system must be an IBM per...

Page 4: ...f 8 to 12 seconds When DIP switch 2 is set to the OFF position to disable the relay pulse feature the Addressable Relay II will remain in the state set by the last command Each Addressable Relay II se...

Page 5: ...nated taps up to 200 feet in length off the main link are permitted but add to the total cable length Make sure that there is a twisted wire pair present that is intended for PowerNet network use Use...

Page 6: ...type in a keyword or product for your particular technical problem in the search box 11 0 WARRANTY AND LIABILITY INFORMATION This instruction booklet is published solely for information purposes and...

Page 7: ...Addressable Relay II IL17435 Rev C Page 1 5 Effective Date 1 05 Effective Date 1 05 For more information visit www eatonelectrical com Page 1 5...

Page 8: ...com Eaton Corporation is a diversified industrial manufacturer with 2003 sales of 8 1 billion Eaton is a global leader in fluid power systems and services for industrial mobile and aircraft equip ment...

Reviews: